Cleaning flue pipes
The flue gas fan and the flue pipe connection should be cleaned at least 2 times
a year, or after about 700 kg of pellets. The flue gas passes are situated on the
side of the combustion chamber, the flue gas duct is located in the lower region
of the combustion chamber.
Remove the convection fins by lifting slightly. The convection fins are only
suspended.
Open and remove the wing nut, which serves to secure the firebox lid. For ease
of disassembly, you should hold up the screw through the combustion chamber.
Open the screw of the sensor tube with an open end wrench 19 and remove the
flame temperature sensor and the sensor tube.
You can now pull the fire room lid forward.
Now clean the flue gas passes on the left and right of the combustion chamber
with the supplied brush.
Vacuum-clean the exposed interior and the side passages of impurities.
After the cleaning of the flue pipes clean the flue gas collector, too!