12.4.2. Horizontal Airflow Direction Control

Operation
Mode
Cooling
Dry
Heating
When heat exchanger
temperature is below 32°C.
When heat exchanger is between
32°C (, incl.) and 56°C (, excl.)
When heat exchanger
temperature is 56°C or more.

12.5. Quiet operation (Cooling Mode/Cooling area of Dry Mode)

A. Purpose
To provide quiet cooling operation compare to normal operation.
B. Control condition
a. Quiet operation start condition
• When "quiet" button at remote control is pressed.
Quiet LED illuminates.
b. Quiet operation stop condition
1. When one of the following conditions is satisfied, quiet operation stops:
a. Powerful button is pressed.
b. Stop by OFF/ON switch.
c. Timer "off" activates.
d. Quiet button is pressed again.
2. When quiet operation is stopped, operation is shifted to normal operation with previous setting.
3. When fan speed is changed, quiet operation is shifted to quiet operation of the new fan speed.
4. When operation mode is changed, quiet operation is shifted to quiet operation of the new mode.
5. During quiet operation, if timer "on" activates, quiet operation maintains.
6. After off, when on back, quiet operation is not memorised.
Horizontal Automatic Operation
• The louver horizontally swings at a fixed
cycle.
Horizontal Automatic Operation
• The louver horizontally swings at a fixed
cycle.
Horizontal Automatic Operation
When the Neural Control is stabilized.
• The louver horizontally swings at a fixed
cycle.
When the Neural Control is not stabilized.
35
Operation for 5 min. after Powerful-ON or
the Neural Control is stabilized.
Operation for 5 min. after Powerful-ON
• The louver horizontally swings at a fixed
cycle.
Operation after Powerful-ON
In Quick Warm Operation
In Warm Heating Operation