12.4. Airflow Direction Control
12.4.1. Horizontal and Vertical Directions
Vertical louver is controlled by remote control: the Vertical Airflow Direction button on the remote controller and by each operation
mode, as shown in the table below.
Manual Operation
• Five-level setting is possible with the remote
controller.
Manual Operation
• Five-level setting is possible with the remote
controller.
Cooling Operation Mode
Vertical Automatic Operation
• The louver swings between the upper limit
and the lower limit.
Dry Operation Mode
Vertical Automatic Operation
• The louver is fixed at 12°.
33
Powerful-ON
• After Powerful is turned on, the louver is
fixed at 26° for 5 minutes or until the Neural
Control is stabilized.
• After the Neural Control is stabilized, the
louver is fixed at 12°.
Power-ON (Automatic Operation)
• The louver is fixed at 12°.