Lincoln Electric AIR VANTAGE 500 CUMMINS Operator's Manual page 26

Hide thumbs Also See for AIR VANTAGE 500 CUMMINS:
Table of Contents

Advertisement

B-9
TABLE B.4 AIR VANTAGE® 500 SIMULTANEOUS WELDING AND POWER LOADS
WELD
AMPS
WATTS
0
12,000
100
12,000
PLUS
200
12,000
250
12,000
300
10,000
400
5,600
500
Current
Voltage
Load
(Amps)
(Volts)
(Watts)
15
120
1800
15
240
3600
20
120
2400
20
240
4800
25
240
6000
30
240
7200
38
240
9000
50
240
12000
OPERATION
1 PHASE
AMPS
50
50
OR
50
50
42
23
0
0
TABLE B.5 AIR VANTAGE® 500 Extension Cord Length
Recommendations
Maximum Allowable Cord Length in ft. (m) for Conductor Size
14 AWG
12 AWG
30
(9)
40
(12)
60
(18)
75
(23)
30
(9)
60
(18)
Conductor size is based on maximum 2.0% voltage drop.
AIR VANTAGE® 500 CUMMINS
3 PHASE
WATTS
AMPS
20,000
50
17,800
43
14,000
34
OR
12,000
29
10,000
24
5,600
13
0
0
10 AWG
8 AWG
75
(23)
125
150
(46)
225
50
(15)
88
100
(30)
175
90
(27)
150
75
(23)
120
100
BOTH 1 AND 3 PHASE
WATTS
AMPS
------
50
------
50
------
50
12,000
------
10,000
------
5,600
------
0
0
6 AWG
(38)
175
(53)
300
(69)
350
(107)
600
(27)
138
(42)
225
(53)
275
(84)
450
(46)
225
(69)
250
(37)
175
(53)
300
(30)
150
(46)
250
125
(38)
200
B-9
4 AWG
(91)
(183)
(69)
(137)
(76)
(91)
(76)
(61)

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents