13

Preadjusting needle height

.06.02
Requirement
In the BDC of the needle bar, the distance between the bottom edge of needle bar 1 and
the needle plate should be approx. 16.5 mm.
Fig. 13 - 04
Position needle bar 1 in the BDC.
Move needle bar 1 (screw 2), without turning it, according to the requirement.
6
3
4
1
5
1
Adjustment
2