Pepperl+Fuchs Ex-DRAGON-D101 Technical Manual page 42

Ex barcode scanner
Table of Contents

Advertisement

Enter configuration
Code 39 Family
disables the family
Read the desired family code
Standard Code 39
Read a check digit selection
CHECK DIGIT TABLE
no check digit control
check digit control and transmission
CODE LENGTH (optional)
The code length selection is valid for the entire Code
39 family.
set code length
The pharmaceutical codes below are part of the Code
39 family but have no check digit selections.
Code CIP39 French pharmaceutical code
page 41
exit and save configuration
Read 4 numbers for the code length where:
First 2 digits = minimum code length.
Second 2 digits = maximum code length.
The maximum code length is 32 characters. The
minimum code length must always be less than or
equal to the maximum.
Examples:
0132 = variable from 1 to 32 digits in the code.
1010 = 10 digit code length only.
Full ASCII Code 39
check digit control without transmission
Code 32 Italian pharmaceutical code
EXDragD101_V104_TH_E.doc