Download Print this page

Electrical Requirements - Rheem 3 Owner's Manual And Installation Instructions

Electric boiling water unit
Hide thumbs Also See for 3:

Advertisement

ELECTRICAL REQUIREMENTS

WARNING
This boiling water unit contains electronic equipment and insulation tests must
only be conducted between neutral and earth or between active and earth.
• 220 – 240 Volts AC, 50 Hz, Single Phase
• 7.5 Amps on 3 Litre
• 10 Amps on 5, 7.5,10 & 15 litre models
• 15 Amps on 25 litre model
• 20 Amps on 40 litre model
A flexible cord is supplied on all 3, 5, 7.5, 10 and 15 Litre models. Do not loosen the
cord grip or pull excess cord into the BWU. If the supply cord of this unit is damaged,
it must be replaced by the manufacturer or a qualified service person.
The 25 and 40 litre models must be installed with fixed wiring. A means of
disconnection from all active (phase) conductors of the power supply must be
incorporated during installation in accordance with the wiring rules.
22

Hide quick links:

Advertisement

loading

This manual is also suitable for:

57.510152540 gallon