1. Check the strength of the installation location.
The wall-hanging bracket weighs approximately 3.0 kg (6.62 lbs.). For the weight of the plasma display
attached to the wall-hanging bracket, please see manual for the plasma display.
While referring to the wall-hanging bracket installation dimensions in the diagram below, check the strength of
the wall in six installation locations, and add reinforcing if any of these locations are not strong enough.
15 (
/
)
19
32
2. Install the wall-hanging bracket to the wall.

Horizontal installation

Fixing screw
(For horizontal installation)
(M5×135)

Vertical installation

Fixing screw
(For vertical installation)
(M5×35)
Fixing screw
(For vertical installation)
(M5×35)
10
775 (30
/
)
33
64
372.5 (14
/
)
372.5 (14
43
64
Wall installation holes (6 locations)
Top notches
(For horizontal installation)
A
Top notches
(For vertical installation)
A
Caution
/
)
15 (
/
)
43
19
64
32
• The wall-hanging bracket has installation
Units: mm
(inches)
• Refer to page 48-51 for the detailed
1. Install the Wall-hanging bracket so that
2. First screw a bolt into the center-top
3. Use a level gauge to correct the
4. Provisionally tighten the fixing screws.
H
Marks
Fixing screw
(For horizontal installation)
(M5×135)
Caution
• If the wall consists of a material such as
Marks
• Use commercially available screws with a
• Secure the screws firmly in at least six
holes provided in 14 locations.
If the wall material will not allow sufficient
strength to be obtained from using six
installation holes, use some of the spare
holes.
However, depending on the construction
material used at the place of installation,
cracks may develop if the screws are
inserted too close to each other.
dimensions that apply when installing the
plasma display.
the Top notches shown on the bracket
is pointing upwards.
hole
.
A
alignment of the wall-hanging bracket,
and then screw bolts into the
remaining five holes.
If the screws are inserted more than 5
mm (
/
inches), it will not be possible
13
64
to install the Plasma Display in the
correct position.
concrete, and bolts or nuts must be
embedded beforehand, determine the hole
positions using the actual wall-hanging
bracket, or calculate hole positions based
on the dimension drawing and then embed
bolts or nuts with a nominal diameter of 6
mm. When embedding bolts, locate so that
the bolts protrude from the wall by 10 to 15
mm (
/
to
/
inches).
25
19
64
32
nominal diameter of 6 mm that are suited to
the wall material you are fitting the bracket to.
places.