RESTORE REPORT CODES ( ✱ 70 – ✱ 76)
✱ 70
ALARM RESTORE RPT CODE
✱ 71
TROUBLE RESTORE RPT CODE
✱ 72
BYPASS RESTORE RPT CODE
✱ 73
AC RESTORE RPT CODE
✱ 74
LOW BAT RESTORE RPT CODE
✱ 75
RF XMTR LO BAT RST RPT CODE
✱ 76
TEST RESTORE RPT CODE
OUTPUT AND SYSTEM SETUP ( ✱ ✱ ✱ ✱ 77 – ✱ ✱ ✱ ✱ 93)
✱ 77 DAYLIGHT SAVINGS TIME
START\END MONTH
✱ 78 DAYLIGHT SAVINGS TIME
START\END WEEKEND
✱ 79, ✱ 80, ✱ 81, ✱ 82 Menu Modes
These are Menu Mode commands, not data fields, for Output Device Mapping, Output Programming, Zone List Programming, and Alpha
Programming respectively. See page 2 and their respective sections in the Installation and Setup Guide for procedures.
✱ 83
TIME ZONE
✱ 84
AUTO STAY ARM
✱ 85
CROSS ZONE TIMER
This option not for use in UL installations.
✱ 86
CANCEL VERIFY KEYPAD DISPLAY
✱ 87
MISC. FAULT DELAY TIME
(used with Configurable Zone Types "digit 6")
✱ 89
EVENT LOG FULL REPORT CODE
✱ 90
EVENT LOG ENABLES
✱ 91
OPTION SELECTION
✱ 92
PHONE LINE MONITOR ENABLE
UL: see Inst. Instructions for requirements
✱ 93
No. OF REPORTS IN ARMED PERIOD
PER ZONE (Swinger Suppression)
[0]
See box on previous page.
|
[11]
See box on previous page.
|
[00]
See box on previous page.
|
[00]
See box on previous page.
|
[11]
See box on previous page.
|
[00]
See box on previous page.
UL: must be enabled if wireless devices are used
|
[00]
See box on previous page.
0 = Disabled
|
[4][10]
1-12 = January-September (1 = Jan, 2 = Feb, etc)
#+10 = October; #+11 = November; #+12 = December
0 = disabled, 1 = first, 2 = second, 3 = third
|
[1][5]
4 = fourth, 5 = last, 6 = next to last, 7 = third to last
0 =Eastern, 1 = Central
[0]
2 = Mountain, 3 = Pacific
0 = no, 1 = partition 1 only
[0]
2 = partition 2 only, 3 = both partitions
0 = 15 seconds
[4]
1 = 30 seconds
2 = 45 seconds
3 = 60 seconds
4 = 90 seconds
5 = 2 minutes
(assign cross zones on zone list 4, with *81 Menu mode)
0 = no, 1 = yes (canceled alarm display is automatically
[1]
disabled if field *199 is set to "1," 2-digit display).
0 = 15 seconds
[0]
1 = 30 seconds
2 = 45 seconds
3 = 60 seconds
4 = 90 seconds
5 = 2 minutes
UL: may only be used on non-burglar alarm/ non-fire alarm
zones when used in fire and/or UL burglar alarm installation
See box on previous page for report code entries.
|
[00]
0 = None; 1 = Alarm/Alarm Restore
[15]
2 = Trouble/Trouble Restore;
4 = Bypass/Bypass Restore;
NOTE : System messages are
8 = Open/Close. Example: To select "Alarm/Alarm
logged when any non-zero
Restore", and "Open/Close", enter 9 (1 + 8); To select
selection is made.
all, enter #15.
0 = None
[9]
1 = Local Lockout
2 = Sounder Delay
E.g. (multiple choice): for AAV
(4) plus Exit Delay restart (8)
4 = AAV UL: must use UVCM module
enter # + 12; for all (1 + 2 + 4 +
8), enter # + 15.
8 = Exit Delay Restart/Reset UL: must be disabled
SIA Installations: Exit Delay should be enabled.
Entry 1:: 0 = disabled, 1-15 = 1 min - 15 min
[0,0]
Entry 2:
0 = Keypad display when line is faulted
1 = Keypad display plus keypad trouble sound
2 = Same as "1", plus programmed output device
STARTS. If either partition is armed, external sounder
activates also. NOTE: Output Device must either be
programmed to be STOPPED in field ✱80 or
STOPPED by Code + # + 8 + output number.
0 = Unlimited Reports
[1]
1 = 1 report pair; 2 = 2 report pairs
SIA Installations: Must be set for option 1 or 2.
– 5 –
6 = 2-1/2 min
7 = 3 min
8 = 4 min
9 = 5 min
#+10 = 6 min
#+11 = 7 min
6 = 2-1/2 min
7 = 3 min
8 = 4 min
9 = 5 min
#+10 = 6 min
#+11 = 7 min
UL: if used, entry delay (*35) must be 30 sec. max.
(#+10 = 10 min; #+11 = 11 min; #+12 = 12 min;
#+13 = 13 min; #+14 = 14 min; #+15 = 15 min)
#+12 = 8 min
#+13 = 10 min
#+14 = 12 min
#+15 = 15 min
#+12 = 8 min
#+13 = 10 min
#+14 = 12 min
#+15 = 15 min