NOTE: Entry of a number other than one specified will give unpredictable results.
For fields *43-*46: Enter 0–9; #+11 for B; #+12 for C; #+13 for D; #+14 for E; #+15 for F. Enter 0 as the first digit of a 4-digit account number for Nos. 0000-0999.
Exit field by pressing ✱ if only 3 digits are used. E.g., For Acct. B234, enter:
43 PARTITION 1 PRIMARY ACCT. No.
44 PARTITION 1 SECONDARY ACCT. No.
45 PARTITION 2 PRIMARY ACCT. No.
46 PARTITION 2 SECONDARY ACCT. No.
47
PHONE SYSTEM SELECT
48
REPORT FORMAT
49
SPLIT/DUAL REPORTING
50
BURGLARY DIALER DELAY
✱ 54
DYNAMIC SIGNALING DELAY
✱ 55
DYNAMIC SIGNALING PRIORITY
∗ ∗ ∗ ∗ 56, ∗ ∗ ∗ ∗ 57, ∗ ∗ ∗ ∗ 58 Menu Modes
These are Menu Mode commands, not data fields, for Zone Programming, Function Key Programming, and Expert Mode Zone Programming
respectively. See page 2 and their respective sections in the Installation and Setup Guide for procedures.
TO PROGRAM SYSTEM STATUS, & RESTORE REPORT CODES (∗ ∗ ∗ ∗ 59 – ∗ ∗ ∗ ∗ 68, ∗ ∗ ∗ ∗ 70 - ∗ ∗ ∗ ∗ 76, & ∗ ∗ ∗ ∗ 89)
For ADEMCO CONTACT ID® Reporting: Enter any digit (other than 0) in the first box, to enable zone to report (entries in the second boxes are
ignored).
A 0 ( not #+10) in the first box disables the report.
For 4+2 Format: Enter codes in both boxes (1
SYSTEM STATUS REPORT CODES ( ✱ 59– ✱ 68)
✱ 59
EXIT ERROR REPORT CODE
✱ 60
TROUBLE REPORT CODE
✱ 61
BYPASS REPORT CODE
✱ 62
AC LOSS REPORT CODE
✱ 63
LOW BAT REPORT CODE
✱ 64
TEST REPORT CODE
✱ 65
OPEN REPORT CODE
✱ 66
ARM AWAY/STAY RPT CODE
✱ 67
RF XMTR LOW BAT REPORT CODE
✱ 68
CANCEL REPORT CODE
#+11| 2 | 3 | 4
| | |
[FFFF]
| | |
[FFFF]
| | |
[FFFF]
| | |
[FFFF]
[1]
[77]
primary
secondary
[0]
[1]
[2]
[0]
UL: see installation instructions for requirements
st
nd
and 2
digits) for 1-9, or #+10 for 0, #+11 for B, #+12 for C, #+13 for D, #+14 for E, #+15 for F
[1]
See box above.
|
[11]
See box above.
|
[00]
See box above.
|
[00]
See box above.
|
[11]
See box above.
|
[11]
See box above. Use Scheduling mode to set periodic test reports.
NOTE: A test report is automatically set for schedule 32 when the
system time is initially set, and the first report is sent 12 hours later;
thereafter the test report is sent every 28 days.
Part. 1 Part. 2 Common
Away Stay
Away Stay
Part. 1
Part. 2
|
[00]
See box on previous page.
UL: must be enabled if wireless devices are used
|
[11]
See box on previous page.
– 4 –
See box above for entries. To clear entries, press * 43 *.
See box above for entries. To clear entries, press * 44 * .
See box above for entries. To clear entries, press * 45 * .
See box above for entries. To clear entries, press * 46 * .
If Cent. Sta. IS NOT on a WATS line:
0=Pulse Dial; 1=Tone Dial;
if Cent. Sta. IS on a WATS line:
2 = Pulse Dial ; 3 = Tone Dial
Select the desired reporting format.
2 = 4+2 ADEMCO L/S STANDARD
7 = 4-digit ADEMCO CONTACT ID® REPORTING
0 = Disable (Backup report only)
Primary Phone No.
1 = Alarms, Restore, Cancel
2 = All except Open/Close, Test Open/Close, Test
3 = Alarms, Restore, Cancel
4 = All except Open/Close, Test All
5 = All
0 = no delay UL: must be "0"
1 = 15 seconds
2 = 30 seconds
3 = 45 seconds
Set delay from 0-225 secs in 15-sec increments.
0 = no delay (both signals sent), 1 = 15 secs,
2 = 30 secs, etc.
UL: Grade AA must be "0;" Grade A must be "15" max
0 = Primary Dialer first; 1 = Long Range Radio first.
For UL Commercial Burglary installations that use a
DACT and LRR, this field must be "0".
[0,0,0]
See box above.
[0,0,0,0,0,0] See box above.
Away Stay
Common
2nd Phone No.
Others
All
All
SIA Installations: delay
must be minimum of
30 seconds

Hide quick links: