First Alert FA168C-GP Programming Manual page 13

Table of Contents

Advertisement

Type 21
Arm-Away
Type 22
Disarm
Type 23*
No Alarm Response
Type 24
Silent Burglary
Type 76
Arm Maximum
Type 77
Keyswitch
Type 81
AAV Monitor Zone
Types 90-93
Installer Defined
*The system can still be armed when these zone types are in a faulted condition.
Schedules
(installer code + [#] + [6] [4]; master code can only access schedules 01-16 and events 00-07
No.
Description
01
02
03
04
05
06
07
08
09
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
Events:
Master/Installer
00 = clear event
01 = device on/off
02 = user access
03 = latch key report
• Arms the system in Away mode when the zone is activated.
• Pushbutton units send the user number to the central station when arming or disarming.
• User code for button must be assigned.
• Disarms the system when the zone is activated.
• User code for button must be assigned.
• Can be used on a zone when an output relay action is desired, but with no accompanying alarm (e.g.,
lobby door access).
• Usually assigned to all sensors or contacts on exterior doors and windows where bells and/or sirens are
NOT desired.
• Provides an instant alarm, with NO audible indication at any keypad or external sounder, if the zone is
faulted when the system is armed in the Away, Stay, Instant, or Maximum modes.
• A report is sent to the central station.
• Arms the system in Maximum mode when the zone is activated.
• Pushbutton units send the user number to the central station when arming or disarming.
• User code for button must be assigned.
• Assign to zone wired to a keyswitch.
Assign to zone connected to AAV module.
Monitors 2-way voice sessions as follows:
- When the zone is faulted, all alarm sounding and dialer reporting stops, except for fire alarms,
which immediately terminate the voice session and cause a fire report to be sent.
- When the zone is restored (session ended), sounding resumes (if bell timeout has not expired)
and reports that were stopped are sent.
• These zone types can be programmed for various custom responses. See data fields *182-*185.
• Types 92 and 93 can only be programmed via the downloader.
UL: Zone types 90-93 may not be used as fire or burglar zones in fire or UL burglar alarm installations.
Event
Device No.
Group Partition Start Time/ Days
Installer Only
04 = forced STAY arm
10 = display custom words 8-10
05 = forced AWAY arm
11 = periodic test report
06 = auto disarm
07 = display "reminder"
– 13 –
Stop Time/ Days
Repeat
Device No. (for 01 event): 01-18
Group No. (for 02 event): 1-8
Partition (for 04-06 events): 1, 2, or 3
Repeat: 0 = none; 1 = repeat weekly
2 = repeat every other week
3 = repeat every third week
4 = repeat every fourth week
Random: 0= no; 1 = yes
Random