✱ 80 OUTPUT DEFINITIONS
Fill in the required data on the worksheet below and follow the programming procedure in the installation manual as you
enter the data during the displays and prompts that appear in sequence.
Notes: 1. For Relays, 4229 and 4204 devices are programmed in *79, *80, and *81 modes.
2. For Powerline Carrier devices (plcd), field
3. Tampers of expansion units cannot be used to operate devices.
Function
No.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
Activated by: 0=delete; 1=zn list; 2=zn type; 3=zn no.; Zone List (ZL): 1-8 = list; Zone Type (ZT): (see table below); Zone No.(ZN): 00=none; 01-64
Partition Number (P)
(if using ZT trig):
Event (for zone list/activated by): By Zone List: 0 = restore; 1 = alarm; 2 = fault; 3 = trouble;
Action: 0 = off; 1 = close 2 secs; 2 = stay closed; 3 = pulse; 4 = toggle; 5 = duration 1
Output Number: 1-18;
Device Type: R = relay; T = trigger; X = X10
ZONE TYPE/SYSTEM OPERATION – Choices for Zone Types are:
00 = Not Used
05 = Trouble Day/Alarm Night
01 = Entry/Exit#1
06 = 24 Hr Silent
02 = Entry/Exit#2
07 = 24 Hr Audible
03 = Perimeter
08 = 24 Hr Aux
04 = Interior Follower
09 = Fire
Choices for System Operation are:
20 = Arming–Stay (RF)
21 = Arming–Away (RF)
22 = Disarming (RF)
31 = End of Exit Time
32 = Start of Entry Time
33 = Any Burglary Alarm
36 = **At Bell Timeout***
Description
Act. by Zn List Zn Type Zn No. Part. (P) By Zn List By Zn No. Action
]
[Fire Zone Reset, using trigger 17
0 = any; 1 = partition 1; 2 = partition 2; 3 = common
10 = Interior w/Delay
12 = Monitor Zone
14 = Carbon Monoxide
15 = 24 Hr Medical/Personal 81 = AAV Monitor Zone
16 = Fire w/Verification
38 = Chime
39 = Any Fire Alarm
40 = Bypassing
41 = **AC Power Failure
42 = **System Battery Low
43 = Communication Failure
52 = Kissoff
27 must be programmed with a House Code.
Activation Type and Detail
[2]
[54]
By Zone No.: 0 = restore; 1 = alarm/fault/trouble
6 = duration 2
††;
23 = No Alarm Response
24 = Silent Burglary
77 = Keyswitch
90-93 = Configurable
54 = Fire Zone Reset
58 = Duress
60 = AAV Trigger
66 = Function key†
67 = Bell Failure
68 = TELCO Line Fault
76 = Arming–Maximum (RF)
78 = Keyswitch Red LED†††
79 = Keyswitch Green LED†††
– 11 –
Event
[0]
†† duration is set in program field *177)
†† (
Note: In normal operation mode:
Code + # + 7 + NN Key Entry starts Device
Code + # + 8 + NN Key Entry stops Device
** Use 0 (any) for Partition No. (P) entry.
*** Or at Disarming, whichever occurs earlier.
† Use *57 Menu mode to assign the function key.
††† Device action not used for these choices.
Out.
Device
No.
Type
[17]