When you want to perform automatic

The unit performs operation automatically while monitoring the temperature and humidity in the room, thus alleviating
the need for advanced operation settings.
Use EASY DEHUMIDIFYING when you want to dehumidify the room and INTELLIGENT LAUNDRY when you want to
dry laundry.
1
Press
The POWER lamp lights.
The current humidity is displayed.
The louvre opens and airfl ow starts.
Press
2
operating mode
Changes with every press.
INTELLIGENT LAUNDRY Operation
Use the swing louvre and make sure that air is
blowing onto all of the clothes
EASY DEHUMIDIFYING Operation
Use the swing louvre as desired.
Press the HUMIDITY SELECTION switch
during operation in EASY DEHUMIDIFYING or
INTELLIGENT LAUNDRY mode to switch to the
AUTO operation.
<To stop operation>
Press
The POWER lamp goes out.
The operating mode indicator
disappears.
Information
12
2
to select the
P16
P13
If the drying inside operation (auto) is
set, it starts after operation stops.
1
The compressor does not activate immediately
after turning the unit off, or after plugging the unit
into the power socket. (This is in order to protect the
compressor.) Dehumidifying begins approximately
3 minutes after you press the POWER switch.
When dehumidifying begins, the operational noise
increases.
The unit remembers the operating mode. Even if the
plug is disconnected or the power turned off, the unit
restarts at the previous setting.

EASY DEHUMIDIFYING

The unit operates intermittently controlling the
airfl ow to remove the damp feeling in the air. When
the room temperature is high, the blower operates
to reduce the rise in room temperature.
Select this when you want to maintain a
comfortable humidity level
Once the set humidity level is reached the airfl ow
and louvre operations will stop.
Rough Guide
on Usage
Keep usage within the ranges specifi ed in "Rough
Guide on Usage" to ensure effi cient drying.
If the room is large, the humidity level may not
fall to the set humidity level.
If the room temperature is below
27°C, the unit changes the set
humidity level according to the
room temperature, and starts
dehumidifying.
P19
If the room temperature is above 27°C, the unit
dehumidifi es until the humidity level reaches 50%,
and then activates the blower. The dehumidifi er is
reactivated when the humidity level rises to 60%.
Up to approx. 21 m
Size of room
60
50
20
27
30
2
Room
Temperature
(°C)