7.4

Air conditioning modes

The roof air conditioner has the following air conditioning modes:
Air conditioning
mode
Automatic
Cooling
Heating
Circulating air
8

Before initial use

Inspection before starting up
Before you switch on the roof air conditioner, observe the following:
➤ Check whether the supply voltage and frequency correspond to the val-
ues specified in the technical data, see page 53.
➤ Ensure both the air intake opening and the air nozzles are free. All venti-
lation grilles must always be kept free to ensure that the roof air condition-
er is able to operate at maximum capacity.
!
CAUTION! Beware of injury
Do not insert your fingers or objects into the air nozzles or the in-
take grille.
Check remote control and insert batteries
➤ Insert the provided batteries in the remote control battery compartment,
see chapter "Replacing the remote control batteries" on page 45.
➤ Check that the four Dip switches (fig. 5 1, page 5) are in the correct
position.
EN
Display
Explanation
message
You specify the temperature, and the roof air
conditioner cools the interior to this temperature
and controls the necessary blower output.
The
You specify the temperature and blower settings,
and the roof air conditioner cools the interior to
this temperature.
You specify the temperature and blower settings,
and the roof air conditioner warms the interior to
this temperature.
You specify the blower level, and the roof air
conditioner blows cold air (cooled circulating air)
into the interior
button is deactivated in this mode.
.