Technical description
6.4

Air conditioning modes

The under-bench air conditioner has the following air conditioning modes:
Air conditioning
mode
Automatic
Cooling
Heating
Circulating air
Dehumidification
Current room
temperature ϑ
Set point:
Conditioning
mode:
16
Display
Explanation
message
In this mode the air conditioner sets the temperature
(set point) automatically and manages the compressor,
heat pump and fan speed by comparing the set point
with the room temperature and it sets the
corresponding conditioning mode (see following
table).
The
You specify the temperature and blower settings, and
the air conditioner cools the interior to this tempera-
ture.
You specify the temperature and blower settings, and
the air conditioner heats the interior to this tempera-
ture.
You specify the blower level, and the air conditioner
blows air into the interior
You specify the temperature, and the air conditioner
cools the interior to this temperature and controls the
necessary blower output and dehumidifys the interior
(Circulating air mode).
The
ϑ ≤ 20 °C
20 °C
Heating or
Circulating air
, + and – buttons are deactivated in this mode.
.
button is deactivated in this mode.
22 °C < ϑ < 25 °C
22 °C
Dehumidification or
Circulating air
FreshWell3000
ϑ ≥ 25 °C
25 °C
Cooling