B1600PLUS, B2200, B2600
15

Technical data

Item no.:
Compressor cooling
capacity:
Heating capacity, only in
230-V~-stationary ope-
ration:
Power consumption
(Cooling/Heating mode)
Rated input voltage:
Current
(Cooling/Heating mode):
Necessary coverage:
Operating temperature
range:
Refrigerant:
Blower:
Protection class:
Max. volume of space in
the vehicle (with insula-
ted walls):
Dimensions L x W x H
(mm), fig. 9, page 6:
Weight:
EN
Dometic
B1600 PLUS
9100100007
1500 W
800 W
620 W/800 W
950 W/1200 W
230 Vw / 50 Hz
2,7 / 3,5 A
0 °C to +52 °C
4 blower levels
20 m³
980 x 650 x 235
(height above vehicle roof)
30 kg
Technical data
Dometic
B2200
9100100009
9102900102
2050 W
1200 W
1200 W/1350 W
4,1 / 5,2 A
4 A, inert
R-407C
IP X4
25 m³
34 kg
Dometic
B2600
2500 W
3300 W
5,2 /5,9 A
30 m³
40,5 kg