Direct Connection; Callback Security Commands - Multitech MultiModem MT5634ZBA-V-V.90 User Manual

Global mt5634zba-series
Hide thumbs Also See for MultiModem MT5634ZBA-V-V.90:
Table of Contents

Advertisement

Extension-Entry Callback
Use this procedure when calling from an extension at the callback number. The password that you use
must be set up for an optional extension-entry callback.
1.
Using a data communications program such as HyperTerminal or PhoneTools, dial the number
of the callback modem.
2.
When the connection is established, the callback modem responds with the following
message:
Password>
3.
Type an extension-entry password, press the plus key (+), type the extension to call back to,
and press E
4.
If the password is valid, the following message appears, and the modems disconnect:
OK Disconnecting
5.
After the delay specified by the #CBDn command, the callback modem calls the extension that
you entered after the + character. If the callback modem is unable to establish a connection, it
tries again, up to the number of attempts specified by the #CBAn command.
6.
After the modems reconnect, the following message reappears:
Password>
7.
Type the same password you used to initiate the call. You are allowed three attempts to enter
the password. After that, you will be disconnected.
8.
If the password is valid, the following message appears, and the modems establish a working
connection:
OK Connecting

Direct Connection

Use this procedure when you want to connect without first being called back. The password that you
use must be set up for an optional direct connection.
1.
Using a data communications program such as HyperTerminal or PhoneTools, dial the number
of the callback modem.
2.
When the connection is established, the callback modem responds with the following
message:
Password>
3.
Type a direct connection password, press the - key, and then press E
attempts or one minute to enter a valid password.
4.
If the password is valid, the following message appears and the modems establish a working
connection:
OK Connecting
Note:
You can make all calls direct connect regardless of whether the password or phone number
has the - character by using the %H1 command

Callback Security Commands

The AT Commands related to Callback to Security are included in the separate AT Commands
Reference guide included on MT5634ZBA-Series Modem system CD.
Multi-Tech Systems, Inc. MT5634ZBA-Series User Guide
. You have three attempts or one minute to enter a valid password.