Code Input Example - Mitsubishi Electric FR-A8AX Instruction Manual

800 series
Hide thumbs Also See for FR-A8AX:
Table of Contents

Advertisement

3.3

Code input example

The following table explains examples of terminal status and input value during BCD code input and binary input.
BCD code input (when the input value is 6325)
Terminal
Terminal input
Digit
name
X0
ON
X1
OFF
1
X2
ON
X3
OFF
X4
OFF
X5
ON
10
X6
OFF
X7
OFF
X8
ON
X9
ON
100
X10
OFF
X11
OFF
X12
OFF
X13
ON
1000
X14
ON
X15
OFF
NOTE
• For BCD code input, the input value of each digit is from 0 to 9. When a value greater than 9 is input, it becomes
invalid and the last value is retained.
• When Pr.304 Digital input and analog input compensation enable/disable selection = any of "0 to 4", X12 to X15
become disabled.
Input value
status
5
2
3
6
Binary input (when the input value is HAB65)
Terminal
Terminal input
name
status
X0
ON
X1
OFF
X2
ON
X3
OFF
X4
OFF
X5
ON
X6
ON
X7
OFF
X8
ON
X9
ON
X10
OFF
X11
ON
X12
OFF
X13
ON
X14
OFF
X15
ON
CONNECTION DIAGRAM AND TERMINAL
Input value
Input value
(hexadecimal)
(decimal)
5
6
43877
B
A
19
3

Advertisement

Table of Contents
loading

Table of Contents