Technical Specifications - Multitech MT202TD User Manual

1200 bps leased line modem
Table of Contents

Advertisement

MT202TD User Guide

Technical Specifications

Your MT202TD modem meets the specifications listed below:
Model Number
Data Rate
Compatibility
Mode of Operation
Line Requirements
Modulation
Carrier Frequencies
Transmit Level
Frequency Stability
Receiver Sensitivity
Timing
6
MT202TD
0–1200 bps
Western Electric 202 and 202T
Data Sets, 202C, 202D, 202E,
202R models
2-wire half duplex or 4-wire full
duplex
2- or 4-wire leased line
unconditioned
Frequency Shift Keyed (FSK)
Mark:1200Hz; Space: 2200Hz;
Soft Carrier: 900Hz
-0 dBm Adjustable to -9 dBm via
Dip switch
±0.01% (crystal controlled)
-40 dBm under worst case
conditions
Request to Send/ Clear to Send:
180 ms
Carrier Detect:
Turn on 30 ms
Turn off 10 ms
Receiver Squelch:
Default 156 ms
Soft Carrier:
Default 25 ms
Minimum 10 ms

Advertisement