Main Connection
MAIN
Inlet
Pilot Adj.
PILOT
Outlet
Rubber Cap
FP1769a
Fig. 51 Remove rubber cap and adjust gas type marker.
5. Turn on gas supply and check that plugs are tight
and leak free.
FP1769
6. Install the enclosed identification label to the valve
AF4000 valve face
2/07
body where it can easily be seen.
Conversion is complete.
10007852
Gas Type Marker
(LP Position Shown)
Minimum
Rate Screw
CO137
�����
������ ����� ����������
����
LDVT Series Direct Vent GaS Fireplace
1. Reassemble the fireplace in the reverse order, ex-
cept for the window frame assembly. Leave this off
until after the unit has been checked for leaks and
the gas supply has been bled.
2. After bleeding the gas line and checking for leaks
with a soap solution, replace the window frame
assembly. Fire up the unit, check for flame impinge-
ment on the logs, adjusting them if necessary. Check
the manifold and supply pressures against the appli-
ance specifications.