Step 8 Wiring The Fireplace - Heat-N-Glo SL-350DVT Installer's Manual

Table of Contents

Advertisement

3/16" PIGGYBACK CONNECTOR
THERMOCOUPLE
Figure 32. Standing Pilot Ignition Wiring Diagram
Step 8. Wiring the Fireplace
NOTE: Electrical wiring must be installed by a licensed
electrician.
CAUTION: DISCONNECT REMOTE CONTROLS IF AB-
SENT FOR EXTENDED TIME PERIODS. THIS WILL PRE-
VENT ACCIDENTAL FIREPLACE OPERATION.
For Standing Pilot Ignition Wiring
Appliance Requirements
• This appliance DOES NOT require 110-120 VAC to operate.
WARNING: DO NOT CONNECT 110-120 VAC TO
!
THE GAS CONTROL VALVE OR REMOTE WALL
SWITCH OR THE APPLIANCE WILL MALFUNC-
TION AND THE VALVE WILL BE DESTROYED.
BLK
BLK
BLK
BLK
TEMPERATURE
SENSOR SWITCH
Figure 33. Fan Wiring Diagram
GAS VALUE
VARIABLE SPEED CONTROL
JUNCTION BOX
BLK
BLK
WHT
BLK
GROUND
GRN
BLK
110-120 VAC
BLACK S2
ON
OFF
ON/OFF
WHITE T2
SWITCH
RED T1
THERMOPILE
BLACK S1
Optional Accessories
Optional fan and remote control kits require that 110-120
VAC be wired to the factory installed junction box before
the fireplace is permanently installed.
Remote Wall Switch
Position the remote wall switch in the desired position on a
wall. Run a maximum of 25 feet (7.8 m) or less length of 18
A.W.G. minimum wire and connect it to the fireplace ON/
OFF switch pigtails.
CAUTION: LABEL ALL WIRES PRIOR TO DISCONNEC-
TION WHEN SERVICING CONTROLS. WIRING ERRORS
CAN CAUSE IMPROPER AND DANGEROUS OPERATION.
VERIFY PROPER OPERATION AFTER SERVICING.
NOTE: IF ANY OF THE ORIGINAL WIRE
AS SUPPLIED WITH THE APPLIANCE
MUST BE REPLACED, IT MUST BE
REPLACED WITH TYPE 105 C RATED WIRE.
BLOWER RECEPTACLE
BLK
WHT
WHT
JUNCTION BOX
FAN
30
REMOTE SWITCH
PIGTAIL
OPTIONAL WALL SWITCH,
THERMOSTAT OR REMOTE
O
BLOWER
SENSOR SWITCH
TEMPERATURE
SPEED CONTROL
(RHEOSTAT)

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sl-350trs

Table of Contents