V
Figure 10. Venting with One 90° Elbow
MODEL SL-350TRS
V (MIN.)
H (MAX.)
90
Elbow on Top
2.5' (863mm)
o
'
1' (305mm)
3
(914mm)
2' (610mm)
4' (1.22m)
3' (914mm)
6' (1.86m)
4' (1.22m)
8' (2.48m)
5' (1.52m)
16' (4.8m)
H MAX. = 16
(4.8m)
'
V + H MAX. = 40
(12.2m)
'
Note: There MUST be a 25%
reduction in total H when using
flex vent.
Use SL D-Series
components only.
Figure 11. Venting with One 90° Elbow
Use D-Series
components only.
17
Note: There MUST be a
25% reduction in total H
when using flex vent.
V
1' MIN. (305mm)
2' MAX. (610mm)
2' MIN. (610mm)
4' MAX. (1.22m)
3' MIN. (914mm)
6' MAX. (1.86m)
4' MIN. (1.22m)
8' MAX. (2.4m)
V+H=40' MAX. (12.4m)
H = 8' MAX. (2.4m)