Gas Installation; Tank Information - Amana SS 5 Use And Care Manual

Burner grill w/ rear burner
Hide thumbs Also See for SS 5:
Table of Contents

Advertisement

L.P. GAS INSTALLATION
Amana™Gas Grills that are set to operate with L.P. gas come with a high capacity hose and
regulator assembly. (Note: Only use the pressure regulator and hose assembly supplied with
the grill or a replacement pressure regulator and hose assemblies specified by Amana™ ).
This assembly is designed to connect directly to a standard 20 lb. L.P. cylinder. L.P. Cylinders are
not included with the grill. L.P. Cylinders can be purchased separately at an independent dealer.
L.P. TANK INFORMATION
Never use a dented or rusted L.P. tank or cylinder with a damaged valve.
L.P. cylinders are equipped with an O.P.D (Overfilling Prevention Device). The device shuts off the
flow of gas to a cylinder after 80% capacity is reached. This limits the potential for release of gas
when the cylinder is heated, averting a fire or possible injury.
The L.P. cylinder must have a shut-off valve terminating in an L.P. gas supply cylinder outlet
specified, as applicable, for connection No. 510 in the standard for compressed gas cylinder valve
outlet and inlet connection ANSI/CSA-V-1. Cylinders must not be stored in a building, garage, or
any other enclosed area. (The L.P. cylinder must have an overfill protection device, OPD, on it.)
The L.P. gas supply cylinder must be constructed and marked in accordance with the specifications
for L.P. gas cylinders of the U.S. Department of Transportation (DOT) or the National Standard of
Canada, CAN/CAS-B339, " Cylinders, Spheres and Tubes for the Transportation of Dangerous
Goods."
L.P. TANK USE
• When turning the L.P. tank on, make sure to open the valve SLOWLY two (2) complete turns to
insure proper gas flow. Most gas tanks now come equipped with a leak detector mechanism
internal to the tank, when gas is allowed to escape rapidly it shuts off the gas supply. Opening the
valve rapidly may simulate a gas leak, causing the safety device to activate, restricting gas flow
causing low flames. Opening the valve slowly will insure this safety feature is not falsely triggered.
• When not in use, gas supply cylinder valve is to be in the " OFF" position.
• The tank supply system must be stored upright to allow for vapor withdrawal.
• The regulator and hose assembly must be inspected before each use of the grill. If there is
excessive abrasion or wear or if the hose is cut, it must be replaced prior to the grill being
used again.
• Cylinders must be stored outdoors out of the reach of children and must not be stored in a
building, garage or any other enclosed area.
• Only a qualified gas supplier should refill the L.P. tank.
• Do not store a spare L.P. gas cylinder under or near the grill.
Gas Requirements
LP hose/
regulator supplied
with complete grill
and cart.
(Type 1
connector)
21

Advertisement

Table of Contents
loading

Table of Contents