iDvF36hn (natural Gas) and iDvF36hP (Propane/LP Gas)
WARNING: If the information in this manual is not
followed exactly, a fire or explosion may result causing
property damage, personal injury or loss of life.
— Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any other
appliance.
— WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any
phone in your building.
• Immediately call your gas supplier from a neighbor's
phone. Follow the gas supplier's instructions.
• If you cannot reach your gas supplier, call the fire
department.
— Installation and service must be performed by a quali-
fied installer, service agency or the gas supplier.
INSTALLER: Leave this manual with the appliance
CONSUMER: Retain this manual for future reference.
For more information, visit www.ironhaus.com or www.desatech.com
MODeLS
Stacked Brick/Standard Glass
herringbone Brick/Standard Glass
Direct vent FirePLAce
OWner'S OPerAtiOn AnD
inStALLAtiOn MAnUAL
This fireplace is manufactured for
Ironhaus under IRONHAUS brand name
by DESA Heating, LLC.

Advertisement

Table of Contents
loading

Summary of Contents for Desa IRONHAUS Yellowstone IDVF36SP

  • Page 1 OWner’S OPerAtiOn AnD inStALLAtiOn MAnUAL Handcrafted Fireplace Systems This fireplace is manufactured for Ironhaus under IRONHAUS brand name by DESA Heating, LLC. The Yellowstone MODeLS iDvF36Sn (natural Gas) and iDvF36SP (Propane/LP Gas) Stacked Brick/Standard Glass iDvF36hn (natural Gas) and iDvF36hP (Propane/LP Gas)
  • Page 2: Table Of Contents

    Parts ..............29 Fireplace Installation.......... 15 Ironhaus Door Enclosure Limited Warranty ..35 Wiring Diagram ..........21 DESA Heating, LLC Warranty ......36 intrODUctiOn Congratulations on your purchase of a 1. Inspect your enclosure and fireplace unit handcrafted Ironhaus Fireplace System and for any damage.
  • Page 3: Safety

    WARNING: Do not use a blow- tion gas fireplace designed for residential ap- er insert, heat exchanger insert plications. This fireplace must be installed with DESA Heating, LLC vent pipe components or other accessory not approved and terminations. for use with this fireplace.
  • Page 4: Local Codes

    SAFety Continued service or repair this fireplace. Have fire- Keep the area around your place inspected annually by a qualified fireplace clear of combustible service person. materials, gasoline and other 5. You must keep control compartments, burners and circulating air passages flammable vapor or liquids.
  • Page 5: Product Features

    PrODUct FeAtUreS These are a few facts that can help you under- • Each time you turn on your fireplace, you stand and enjoy your direct vent fireplace: may notice some amount of condensation on the inside of the fireplace glass. This •...
  • Page 6 Pre-inStALLAtiOn Continued • There must not be any obstruction such as If you are using a separate combustible man- bushes, garden sheds, fences, decks or tel piece, refer to Figure 6 for proper instal- utility buildings within 24" from the front of lation height.
  • Page 7: Location Of Termination Cap

    LOcAtiOn OF terMinAtiOn cAP Fixed Openable Fixed Closed Closed Openable TERMINATION CAP GAS METER RESTRICTED AREA AIR SUPPLY INLET (TERMINATION PROHIBITED) A = clearance above grade, veranda, porch, deck, or I = clearance to service regulator vent outlet [*72" (182.9 cm) balcony [*12"...
  • Page 8: Requirements For The Commonwealth Of Massachusetts

    reqUireMentS FOr the cOMMOnWeALth OF MASSAchUSettS For all side wall horizontally vented gas fueled INSpECTION equipment installed in every dwelling, building or The state or local gas inspector of the side structure used in whole or in part for residential wall horizontally vented gas fueled equipment purposes, including those owned or operated by shall not approve the installation unless, upon...
  • Page 9: Venting Installation

    These models are tested and approved for use with DESA Heating, LLC (direct vent) pipe INSTALLATION pRECAUTIONS components and terminations. • Wear gloves and safety glasses for The venting system must terminate on the...
  • Page 10: Venting Installation

    ventinG inStALLAtiOn Continued INSTALLATION pLANNING Center of hole should line up with center line of horizontal vent pipe. Mark wall for There are two basic types of direct vent an 11 " x 11 " square hole. Cut and installation: frame square hole in exterior wall where •...
  • Page 11 ventinG inStALLAtiOn Continued Carefully move fireplace, with vent as- WARNING: Do not recess sembly attached, toward wall and insert vent pipe into horizontal termination. Pipe vent termination into any wall. overlap should be a minimum of 1 " (see This will cause a fire hazard. Figure 13, page 12).
  • Page 12 ventinG inStALLAtiOn Continued GROUND FLOOR INSTALLATION Minimum Siding Recommended Applications: Pipe Standoff Overlap • Installation using cabinet surrounds Direct Screws " Vent • Through the wall using round or square Pipe termination (up to 12" adjustable pipe) Wall • NOT FOR CORNER INSTALLATION Firestop 90°...
  • Page 13 ventinG inStALLAtiOn Continued Vertical Termination Installation Flat Ceiling Installation Note: Vertical restrictor must be installed in 1. Cut a 11 " square hole in ceiling using all vertical installations. locating hole as a center point. Opening should be framed to 11 "...
  • Page 14 Flex Using Hi-Temp Duct Tape Figure 19 - Outside Air Flex Duct Installation HIGH ALTITUDE INSTALLATION Your DESA Heating, LLC direct vent fireplace Vertical has been tested and approved for elevations Venting from 0-2000 feet (USA). V = 40' max.
  • Page 15: Fireplace Installation

    Continued PARTS LIST FOR VENTING KITS Number Description VT-58 Vertical Round Termination, AND COMpONENTS Galvanized DESA (5"/8") Pipe & Vent Kits SC-58 Storm Collar, Galvanized Number Description WF-58 Wall Firestop, Galvanized P58-6 6" Section Double Wall Pipe, RF-58-6...
  • Page 16 FirePLAce inStALLAtiOn Continued For propane/LP connection only, the installer Apply pipe joint sealant lightly to male NPT must supply an external regulator. The exter- threads. This will prevent excess sealant from nal regulator will reduce incoming gas pres- going into pipe. Excess sealant in pipe could sure.
  • Page 17 FirePLAce inStALLAtiOn Continued CONNECTING FIREpLACE TO GAS pRESSURE TESTING GAS SUppLY pIpING SYSTEM SUppLY Test Pressures In Excess Of 1/2 PSIG Installation Items Needed (3.5 kPa) • 5/16" hex socket wrench or nut-driver 1. Disconnect fireplace and its individual • sealant (resistant to propane/LP gas, not equipment shutoff valve from gas supply provided) piping system.
  • Page 18: Safety

    FirePLAce inStALLAtiOn Continued Equipment REMOVING/REPLACING GLASS Shutoff Valve DOORS Propane/LP CAUTION: Do not operate Supply Tank this fireplace with a broken glass door panel or without the glass door panel securely in place. For replacement part informa- tion see Replacement Parts, page 34.
  • Page 19 FirePLAce inStALLAtiOn Continued Side Bricks Side Trim Side Left Trim Bottom Brick Side Bricks Middle Bottom Brick Right Bottom Brick Figure 26 - Removing/Installing Brick, Side Trim and Screen Unlock Lock Glass Door Figure 27 - Removing/Installing Glass Door LAVA ROCK, EMBER FLAKES AND 1.
  • Page 20 FirePLAce inStALLAtiOn Continued 3. Place ember flakes around front and sides REMOTE CONTROL INSTALLATION of burner and on burner ports (see Figure (MODEL WRC) 29). This will create the glowing ember ap- 1. Remove center brick/control cover. pearance as the flame touches the ember 2.
  • Page 21: Wiring Diagram

    WirinG DiAGrAM PILOT SAFETY SHUTOFF IGNITOR LEAD SWITCH ORANGE BLUE TRANSFORMER WHITE BLACK GROUND GREEN ADAPTER/ REMOTE RECEIVER J-BOX OPerAtiOn FOR YOUR SAFETY C. Do not use this appliance if any part READ BEFORE LIGHTING has been under water. Immediately call a qualified service technician to inspect WARNING: If you do not fol- the appliance and to replace any part of...
  • Page 22: Inspecting Burners

    OPerAtiOn Continued 6. Wait five (5) minutes to clear out any gas. Then smell for gas, including near the Sensing Pilot floor. If you smell gas, STOP! Follow “B” Burner in the safety information on page 21. If Ignitor you don't smell gas, go to the next step. 7.
  • Page 23: Cleaning And Maintenance

    inSPectinG BUrnerS Continued If the vent configuration is installed incorrectly, flames will lift or "ghost". This can be danger- ous. Inspect flames after installation to ensure proper installation and performance. Figure 36 shows a typical flame pattern. If burner flame pattern differs from that de- scribed: •...
  • Page 24: Specifications

    cLeAninG AnD MAintenAnce Continued LOGS CAUTION: Do not vacuum if • Use a vacuum cleaner to remove any pieces are hot. carbon buildup on logs. • Replace material periodically as needed. Use only glass door replacement intended for See Replacement Parts, page 34. this fireplace (see Replacement Parts, page VENTING SYSTEM 34 for detail on ordering).
  • Page 25: Troubleshooting

    trOUBLeShOOtinG WARNING: Turn off fireplace and let cool before servicing. Only a qualified service person should service and repair fireplace. CAUTION: Never use a wire, needle or similar object to clean pilot. This can damage pilot unit. Note: All troubleshooting items are listed in order of operation. OBSERVED PROBLEM pOSSIBLE CAUSE REMEDY...
  • Page 26: Troubleshooting

    trOUBLeShOOtinG Continued OBSERVED PROBLEM pOSSIBLE CAUSE REMEDY Pilot will not stay lit 1. Loose wiring on ignitor wire 1. Check wiring connection. to ignition module and/ Refer to wiring diagram or poor ground to ignition (see Wiring Diagram, page module 21) and/or check ground wire to ignition module 2.
  • Page 27 trOUBLeShOOtinG Continued WARNING: If you smell gas • Shut off gas supply. • Do not try to light any appliance. • Do not touch any electrical switch; do not use any phone in your building. • Immediately call your gas supplier from a neighbor’s phone. Fol- low the gas supplier’s instructions.
  • Page 28 PArtS MODELS IDVF36SN, IDVF36SP, IDVF36HN, IDVF36HP www.ironhaus.com or www.desatech.com 123129-01A...
  • Page 29 PArtS This list contains replaceable parts used in your fireplace. When ordering parts, follow the instructions listed under Replacement Parts on page 34 of this manual. PART NO. DESCRIpTION 121063-01 Andiron • • • • 110037-01 Electrical Duct Assembly • •...
  • Page 30 PArtS BURNER ASSEMBLY MODELS IDVF36SHN, IDVF36SHP, IDVF36SN, IDVF36SP, IDVF36HN, IDVF36HP www.ironhaus.com or www.desatech.com 123129-01A...
  • Page 31 PArtS BURNER ASSEMBLY MODELS IDVF36SHN, IDVF36SHP, IDVF36SN, IDVF36SP, IDVF36HN, IDVF36HP This list contains replaceable parts used in your fireplace. When ordering parts, follow the instructions listed under Replacement Parts on page 34 of this manual. NO. PART NO. DESCRIpTION QTY. Bottom Pan Weldment •...
  • Page 32 PArtS REFRACTORY pARTS MODELS IDVF-36SN, IDVF-36SP, IDVF-36HN, IDVF-36HP www.ironhaus.com or www.desatech.com 123129-01A...
  • Page 33 PArtS This list contains replaceable parts used in your fireplace. When ordering parts, follow the instructions listed under Replacement Parts on page 34 of this manual. NO. PART NO. DESCRIpTION 102520-01 Refractory Retainer • • • • 120248-01 Left Refractory •...
  • Page 34: Replacement Parts

    A list of authorized dealers can be found by replacement part(s), call DESA Heating, LLC visiting www.desatech.com. at 1-866-672-6040. When calling Ironhaus or DESA Heating, LLC, When calling DESA Heating, LLC, have have ready: ready: • model and serial numbers of your heater •...
  • Page 35: Ironhaus Door Enclosure Limited Warranty

    irOnhAUS DOOr encLOSUre LiMiteD WArrAnty iMPOrtAnt! PLeASe reAD thiS WArrAnty BeFOre inStALLinG Or USinG irOnhAUS PrODUctS! IRONHAUS products, i.e., furnishings (not glass, finish, mesh parts and accessories sold separate from) are warranted to retail purchaser-user to be free from defects on material and workmanship for as long as you own your home (where enclosure was originally installed).
  • Page 36 This is DESA Heating, LLC’s exclusive warranty, and to the full extent allowed by law; this express warranty excludes any and all other warranties, express or implied, written or verbal and limits the duration of any and all implied warranties, including warranties of merchantability and fitness for a particular purpose to two (2) years on new products and 30 days on factory reconditioned products from the date of first purchase.