Specifications - Desa IRONHAUS Yellowstone IDVF36SP Owner's Operation And Installation Manual

Table of Contents

Advertisement

CAUTION: Do not vacuum if
pieces are hot.
Use only glass door replacement intended for
this fireplace (see Replacement Parts, page
34 for detail on ordering). No substitutions
may be made. See Removing/Replacing
Glass Doors, page 18 for instructions for
replacing glass doors.
WARNING: Do not operate
fireplace with glass door un-
latched, removed, cracked or
broken.
pILOT AND BURNERS
• Remove material before cleaning burners
and replace when cleaning is complete.
• Burner and controls should be cleaned
with compressed air to remove dust, dirt
or lint.
• Use a vacuum cleaner or small, soft bristled
brush to remove excess dust, dirt or lint.
IDVF-36S-N, IDVF-36H-N
• Rating: 66,000 Btu/hr
• Gas Type: Natural Gas Only
• Ignition: Electronic
• Manifold Pressure: 3.5" w.c.
• Minimum Inlet Supply Pressure: 7" w.c.
24
cLeAninG AnD MAintenAnce

SPeciFicAtiOnS

www.ironhaus.com or www.desatech.com
Continued
LOGS
• Use a vacuum cleaner to remove any
carbon buildup on logs.
• Replace material periodically as needed.
See Replacement Parts, page 34.
VENTING SYSTEM
Conduct annual inspection of the venting
system following these guidelines:
1. Check areas of venting system that are
exposed to the weather for corrosion (rust
spots or streaks and, in extreme cases,
holes). Have these items replaced im-
mediately by a qualified service person.
2. Remove the vent cap and shine a flash-
light into the vent. Remove any foreign
material.
3. Check for evidence of excessive con-
densation. Continuous condensation can
cause corrosion of caps, pipes and fittings
and can be caused by having excessive
lateral runs, too many elbows or exterior
portions of the system being exposed to
cold weather.
4. Inspect joints to verify that no pipe section
or fitting has been disturbed and loos-
ened. Check mechanical supports such
as wall straps for rigidity.
IDVF-36S-P, IDVF-36H-P
• Rating: 62,000 Btu/hr
• Gas Type: Propane/LP Gas Only
• Ignition: Electronic
• Manifold Pressure: 10" w.c.
• Minimum Inlet Supply Pressure: 11" w.c.
123129-01A