11
12
13
14 15
Fig. 7.46
• Scroll the various parameters using keys
17 or 18 until the letters P12 are displayed
on the LCD display and the value of the
parameter (74=Inovia 25C ERP, 78=Inovia
30C ERP or 84=Inovia 35C ERP), indicat-
ing that "parameter 12" (Fig. 7.47) has been
activated.
Fig. 7.47
• It is possible to modify parameter using keys
11 or 12 (Fig. 7.46) (Refer to Fig. 7.44 and
determine the correct Value appertaining to
the output required for the central heating
requirement.).
• By pressing key 14 (Fig. 7.46) confirmation
of the inserted value is obtained.
• Press keys 17 or 18 (Fig. 7.46) to exit with-
out changing the value.
• Exiting the "programming mode" is auto-
matic, after 15 minutes, or by cutting power.

7.19 Setting record

Important: at the end of the setting opera-
tion it is important to fill/update the table
(Fig. 7.48).
This to allow a correct setting of this boiler
in case of replacement of the main control
- 76 -
COMMISSIONING
p.c.b.
18
PARAMETER
Boiler type
17
Water sensors con-
figuration
16
Pump management
TA/OT zone manage-
ment
Gas type
Not used
C.h. flow max temper-
ature °C
Factory
reset
Chimney sweep func-
tion
C.h.
quency
C.h. pump post-circu-
lation
Max. useful output in
c.h. mode
C.h. pump working
type
Ignition power
K
probe diagram)
Regulation of the mini-
mum heating power
D.h.w. burner turn off
function
NTC on the c.h. return
User interface
Not used
Not used
Not used
Not used
Not used
Not used
DIGIT
P 01
P 02
P 03
P 04
P 05
P 06
P 07
parameters
P 08
P 09
reignition
fre-
P 10
P 11
P 12
P 13
P 14
value
(external
P 15
P 16
P 17
P 18
P 19
P 20
P 21
P 22
P 23
P 24
P 25