Electric Connection - Biasi Inovia 25C ERP User Manual And Installation Instructions

Wall hung, fanflue, roomsealed, high efficiency gas boiler
Hide thumbs Also See for Inovia 25C ERP:
Table of Contents

Advertisement

Pluming kit B (Fig. 6.13) (Fig. 6.14)
Co-axial ø 60/100 mm + vertical part ø 60 mm
(flue outlet).
This kit allows the combustion air to be sucked
up and expel the burnt gases directly to the
outside through a telescopic co- axial flue
(450-950 mm).
90° =--- 0,85 m
ø 60 mm
45° =--- 0,65 m
Fig. 6.13
In the last section, the fumes are expelled
through a vertical section.
Extensions and elbows can be added to ex-
tend the kit's length.
The chart of Fig. 6.14 gives the allowable
dimensions of the ducts "a" and "b" of (Fig.
6.13).
INSTALLATION
90° =--- 1 m
ø 60/100 mm
45°
=--- 0,5 m
"a" vertical length (m)
11
10
9
8
7
6
5
4
Allowedvalues
o
3
2
1
0
0
1
2
3
4
Fig. 6.14
Each additional elbow reduces the overall ac-
ceptable length of the flue system as follows:
45° (60/100 mm) reduce length by 0,5 m.
90° (60/100 mm) reduce length by 1 m.
45° (60 mm) reduce length by 0,65 m.
90° (60 mm) reduce length by 0,85 m.
6.9

Electric connection

• Unscrew screws "W" and remove the front
panel "X" by pulling it and pushing it towards
the top so that it is freed from the top hous-
ing Fig. 6.15.
d
e
5
6
7
8
9
10
"b" horizontal length (m)
- 57 -
11