• Press keys 14 - 15 - 16 (Fig. 7.45) at the
same time for 10 seconds to exit the "pro-
gramming mode".

7.19 Setting record

Important: at the end of the setting op-
eration it is important to fill/update the
table (Fig. 7.49).
This to allow a correct setting of this
boiler in case of replacement of the main
control p.c.b.
PARAMETER
Boiler type (to be
updated with the
complete range)
Not used
Pump speed
Not used
Gas type
Not used
C.h. flow max tem-
perature °C
Factory
param-
eters reset
Chimney
sweep
function
C.h. reignition fre-
quency
C.h. pump post-
circulation
Max. useful output
in c.h. mode
C.h. pump working
type
Ignition power
K value (external
probe diagram)
Not used
D.h.w. burner turn
off function
- 72 -
COMMISSIONING
DIGIT
VALUES
Pr 01
Pr 02
---------------
Pr 03
Pr 04
---------------
Pr 05
Pr 06
---------------
Pr 07
Pr 08
Pr 09
Pr 10
Pr 11
Pr 12
Pr 13
Pr 14
Pr 15
Pr 16
Pr 17
PARAMETER
NTC on the c.h.
return
LCD type
Not used
Not used
Not used
Not used
Not used
Not used
Not used
C.h. minimum set-
point
Maintenance inter-
vals
NTC inlet probe
Correct
pressure
c.h. system
Fig. 7.49
• Enter the "programming mode" by press-
ing keys 14 - 15 - 16 (Fig. 7.50) for 10
seconds at the same time until the let-
ters Pr that alternate with code 01 are
displayed on the LCD display, indicating
that "parameter 01" (Fig. 7.51) has been
activated.
12
13
Fig. 7.50
DIGIT
VALUES
Pr 18
Pr 19
Pr 20
---------------
Pr 21
---------------
Pr 22
---------------
Pr 23
---------------
Pr 24
---------------
Pr 25
---------------
Pr 26
---------------
Pr 27
Pr 28
Pr 29
Pr 30
16
15
14