Starting The Engine In Manual Mode - MTU 12 V 4000 T95 Operating Instructions Manual

Table of Contents

Advertisement

4.4 Starting the engine in manual mode

Preconditions
☑Engine is not under load.
☑External start interlock is not activated.
DANGER
Rotating, moving engine parts.
Risk of crushing! Risk of body parts being caught or drawn in!
• Before barring with the starting system, make sure that no one is in the danger zone of the en-
gine.
WARNING
Loud engine noises with the engine running:
Risk of hearing damage!
• Wear ear protection.
Preparation
Item
Coolant preheater
Starting the engine
Item
Control cabinet, operator
station etc. (depending on
manufacturer)
36 | Operation | MS150120/00E 2014-11
Measure
Switch on (if available; see manufacturer's documentation).
Measure
1. If there is a coolant preheater, make sure that the coolant tempera-
ture > 40 °C (see manufacturer's documentation).
2. Press the start key (see plant documentation).
• Automatic starting sequence is executed.
• Engine speed instrument indicates increasing speed.
• After the starting sequence is completed, engine runs at idle
speed.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents