Electrical Connection; Overload Protector - Dimplex RCE 050 Installation And Operating Instructions Manual

Radiant convector
Table of Contents

Advertisement

Available languages

Available languages

Fig.3
Type
Dimension A
(mm)
RCE 050
RCE 100
RCE 150
RCE 200
Installation on wooden walls is permissible.
All models are splash-water protected in accordance
with the IP24 standard and can be used in bathrooms
in protection zone II.
The supply connection socket must be accessible after
installation.
ATTENTION!
The original wall bracket supplied on the rear of the
device must be used!
www.dimplex.de/en
Fig.2
Dimension B
(mm)
513
225
675
387
756
468
918
630
RCE050_200_gb · 04/15/A
RCE 050, RCE 100, RCE 150, RCE 200
Remove the wall bracket from the rear of the device
by pressing the springs on each side. (see Fig. 2.)
Drill the fastening holes. Look out for electric cables
or pipework in the wall.
Screw the wall bracket securely to the wall with the
accompanying screws.
Hook the device into the bottom slots on the wall
bracket.
Bring the device into an upright position and press
the device into the springs until they engage to lock
in place.
ACHTUNG!
Please note that burning cigarettes, candles and oil
lamps, in conjunction with the convection of electric
heating systems, can cause soot deposits on the wall
and on the surface of the device. This is not a device
malfunction.

5 Electrical connection

The current regulations according to VDE 0100 part
701 and the relevant installation requirements must be
observed. The heating devices are equipped with a de-
vice connection cable, type H05VV-F, 4 x 1.0 mm
without a plug.
Wire assignment of the device connection cable:
Green/yellow: 'PE' protective conductor
Blue:
'N' - neutral conductor supply voltage
Brown:
'L' - phase supply voltage
Black:
Pilot wire
ATTENTION!
The pilot wire has no function and must be isolated
correctly! Do not earth the pilot wire!
The device connection cable must be connected to a
connection socket which is suitable for the heating de-
vice. A disconnecting device with a contact opening of
at least 3 mm at each pole (e.g. circuit breaker) must
be provided in the permanently installed wiring.

6 Overload protector

For your safety, the heating device is equipped with an
overload protector. If the air circulation is interrupted,
the overload protector switches off the heating device.
After sufficient cooling, the heating device switches on
again automatically.
If the overload protector is triggered multiple times, the
cause must be determined (e.g. ventilation grill cov-
ered).
The triggering of the overload protector is shown in the
display by a red flashing indicator light.
To reset the display, remove the cause of the overheat-
ing and press the ENTER key for 10 seconds.
2
,
EN-15

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rce 100Rce 150Rce 200

Table of Contents