Installation; Electrical Connection; Operation - Dimplex DX 521 Installation And Operating Instructions Manual

Free-standing convector
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 5
English
ATTENTION!
If the device switches on automatically unsu-
pervised, risks may arise, e.g. devices that
have been covered or adjusted could result
in fires!
ATTENTION!
Do not use the device on long-pile carpets.
Keep flammable objects, such as curtains or
other textiles, a sufficient distance away
from the heating device. Do not use the de-
vice for drying clothes!
NOTE
Use device for room heating within enclosed rooms
only.

2. Installation

ATTENTION!
Do not set up the device directly below a wall
socket.
ATTENTION!
Only set up the device on a horizontal, stable
surface.
230
585
Min.
The minimum clearances must be observed.
In addition, a clearance of 750 mm is to be maintained
in front of the unit.
The supply connection socket must be accessible
after installation.
Make sure that the inflow and outflow of air at the top
and bottom of the device are unimpeded
EN-6
230
Min.
233
.
2203/A
2.1. Installation of the supporting feet
Do not install the heating device without the feet sup-
plied.
The two mounting screws for the supporting feet are
located on the bottom of the device.
Loosen the mounting screws.
Engage the supporting feet as shown in the illus-
tration and tighten the screws.

3. Electrical connection

The voltage specified on the type plate must match
the line voltage.
The cable must not be in contact with the casing.
The device must only be repaired by a qualified elec-
trician in accordance with the applicable safety regu-
lations.
Connect the device directly to an earthed socket. Do
not use an extension cable
The plug must always be accessible in case of emer-
gencies.

4. Operation

Both models have two rotary knobs.
The top rotary knob can be used to select three or four
heating levels depending on the model:
Mode
Operation
O
Off
I
1.2 kW
II
2.0 kW
2.0 kW with turbo fan (DX 522 T only)
The room temperature is regulated using the infinitely
adjustable thermostat (bottom rotary knob).
If the rotary knob is set to the lowest setting i.e. to the
extreme left, the thermostat switches the heating de-
vice on at an ambient temperature of approx. 5 °C.
Turbo fan
(DX 522 T only)
Rotary knob for
selecting the
heating levels
Thermostat
rotary knob
DX 521, DX 522 T
DX 521
rotary knob
DX 522 T
rotary knob
www.dimplex.eu

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dx 522 t

Table of Contents