Energy Saving Functions; Dual Circuit Heating Element; Open Window" Function; Learning Function - Dimplex RCE 050 Installation And Operating Instructions Manual

Radiant convector
Table of Contents

Advertisement

Available languages

Available languages

RCE 050, RCE 100, RCE 150, RCE 200
ATTENTION!
In order to avoid a hazard due to inadvertent
resetting of the thermal cutout, this appliance
must not be supplied through an external
switching device, such as a timer or
connected to a circuit that is regularly
switched on and off by the utility.
ATTENTION!
Connection only to fixed installed cables! The
hardwired electrical installation must be
provided with a disconnect device with a
contact grap of at least 3 mm at each pole
(e.g. automatic circuit breaker)!
ACHTUNG!
The device must be earthed!

2 Energy saving functions

2.1 Dual circuit heating element

The Dimplex RCE radiant heat convector has a con-
vection heating element and a radiant heating system.
This combination enables just the radiant heating to be
used if the temperature difference is low. This mini-
mises the risk of overheating the room, which saves
energy.

2.2 "Open Window" function

If a window or a door is left open by mistake, the control
will detect the sudden temperature fluctuations and
switch to Standby mode. If the window or door is
closed, the device returns to normal mode. This func-
tion interrupts the heating operation to prevent heat
from escaping from the room in an uncontrolled man-
ner. This saves money and minimises energy con-
sumption.

2.3 Learning function

This function enables the heating device to be switched
on early to ensure that the desired temperature is
reached at the time specified in the program.
Example: A temperature of 21°C is set for mornings at
7 am in the time program. The heating device now de-
termines how long it takes to reach the desired temper-
ature at the specified time based on its "experience".
NOTE
NOTE
If the Anticipatory (ES) function is activated, the device
heats for the pre-set time to ensure that the room has
reached the required temperature at the right time.

Technical Device Description.

EN-14
3 Technical device description
Type
RCE 050
RCE 100
RCE 150
RCE 200
Connection voltage
Temperature controller
Protection class
Degree of protection

4 Assembly, installation, minimum clearance

The radiant heat heating device is designed for wall
mounting using the wall bracket provided. The device
may only be installed in upright position as shown in
Fig. 1 - 3.
Caution with inflammable objects. The minimum clear-
ances must be complied with. A distance of at least
500mm must be complied with on the front of the de-
vice.
RCE050_200_gb · 04/15/A
Output
Output
radiant
convector
heating
heating
200 W
300 W
300 W
700 W
300 W
1200 W
350 W
1650 W
1/N/PE~230-240V, 50Hz
7 - 32°C
Protective conductor con-
nection
IP24
Fig.1
www.dimplex.de/en
Total
output
500 W
1000 W
1500 W
2000 W

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rce 100Rce 150Rce 200

Table of Contents