A.c. Generator - TGB BR8 Service Manual

Table of Contents

Advertisement

Assembly: Assembly is in reverse order
of disassembly procedures.
Watch:
(1) Apply grease to the ends of armature
shaft.
(2) Apply grease to the dust seal before
assembly front cover.
(3) The flange of front cover should match
the fillister of motor shell.
5-7 A.C. GEMERATOR
(A) A.C. generator coil
Disassembly: Disconnect the A.C.
generator's 4P connector.
Measure:
A. Use megga meter's positive terminal
to connect the white wire of the 4P
connector.
B. Connect the megga meter's
negative terminal with frame ground
and measure the resistance.
Note:
(1)
Standard resistance: 0.2~1.0 Ohm
o
(20
C).
(2) If the measured value exceed the
standard, replace with new A.C.
generator charging coil.
(B) A.C. generator lighting coil
Disassembly: Disconnect the A.C.
generator's 4P connector.
Measure:
A. Use megga meter's positive terminal
to connect the yellow wire of the 4P
connector.
B. Connect the megga meter's
negative terminal with body ground
and measure the resistance.
Note:
(1) Standard resistance: 0.1~1.0 Ohm (20
(2) If the measured value exceeds the standard, replace with new A.C. generator lighting
coil.
o
C).
92