Revision History Changes to the original manual are listed below: Version Date Description of Version September 9, 2010 Initial release February 18, 2011 Added Blink mode selections. Advanced Handheld CCD/Laser Scanner...
Page 4
Important Notice No warranty of any kind is made in regard to this material, including, but not limited to, implied warranties of merchantability or fitness for any particular purpose. We are not liable for any errors contained herein nor for incidental or consequential damages in connection with furnishing, performance or use of this material.
Laser Safety This equipment generates, uses and can radiate radio frequency energy. If not installed and used in accordance with the instructions in this manual, it may cause interference to radio communications. The equipment has been tested and found to comply with the limits for a Class A computing device pursuant to EN55022 and 47 CFR, Part 2 and Part 15 of FCC Rules.
ROGRAMMING UIDE About This Guide This programming guide applies to various handheld scanners, including * Advanced Handheld Contact CCD Scanner, * Advanced Middle-Range Handheld CCD Scanner, * Advanced Handheld Laser Scanner, and * Advanced Handheld High-Speed Laser Scanner Some settings are not available for certain models. If you are not sure about the model of your scanner at hand, refer to the device label or contact your distributor.
ROGRAMMING UIDE Introduction to Scanner Configuration Scanning a series of programming barcode labels can configure the series scanners. This allows decoding options and interface protocols to be tailored to a specific application. The configuration is stored in non-volatile memory and will not be lost by removing power from the scanner.
ROGRAMMING UIDE Default Parameters This table gives the default settings of all the programmable parameters. The default settings would be restored whenever the laser scanner reads the "Reset" programming label in programming mode. If you wish to change any setting, scan the appropriate barcodes below.
ROGRAMMING UIDE GS1 DataBar Expanded identifier code PDF417 identifier code Barcode Length Codabar maximum Code 11 Standard 2 of 5 minimum Industrial 2 of 5 Matrix 2 of 5 Code 39 maximum Code 93 minimum Code 128 maximum Chinese Post Code minimum maximum ITF 2 of 5...
ROGRAMMING UIDE Programming Procedure Below is the programming procedure by using barcodes in this guide. 1. Power up the scanner. Scan the Start of Configuration barcode. Scan the barcode for the desired feature. Multiple features can be enabled/disabled before scanning the End of Configuration barcode. Scan the End of Configuration barcode and save the new configuration.
ROGRAMMING UIDE Parameter Setting Start Of Configuration Scanner Operation System Function Setting Barcode Barcode Label Description Value Reset (return to factory default) Display firmware version Abort :exit programming mode with no update KE94 Return to customer default KE95 Save as customer default End Of Configuration Advanced Handheld CCD/Laser Scanner...
Page 14
ROGRAMMING UIDE Start Of Configuration Interface Setting Barcode Barcode Label Description Value KE97 Return to USB default KE99 Return to RS-232 default KE87 Enable USB virtual COM (Virtual COM driver required. For installation steps refer to Appendix 1.) KE01 Enable IBM PC/AT/PS/2 Keyboard emulation KE05 Enable stand-alone keyboard (Required no keyboard or key simulator.
Page 15
ROGRAMMING UIDE Start Of Configuration General Scan Mode Setting Handheld Operation Barcode Barcode Label Description Value SM01 Trigger Mode The scanner becomes inactive as soon as the data is transmitted. It must be triggered to become active again. SM02 Auto Scan Mode The scanner is still active after the data is ...
Page 16
ROGRAMMING UIDE Start Of Configuration Scan Mode Only Available for Handheld High-Speed Laser Scanner Handheld Operation Barcode Barcode Label Description Value SM07 Auto Trigger Mode The scanner will automatically detect object and activate laser lighting. Barcode data is transmitted when the trigger is pressed. SM08 Aim Mode When the trigger is pressed once, the scanner...
ROGRAMMING UIDE Start Of Configuration Operation Function Setting Good Read Beeper Tone Selection Barcode Barcode Label Description Value GR02 Low beeper tone GR01 Medium beeper tone GR03 High beeper tone GR05 Speaker disable Beeper Sound Selection Barcode Barcode Label Description Value GR13 Very short (5 msec)
Page 18
ROGRAMMING UIDE Start Of Configuration Beeper Volume Selection Barcode Barcode Label Description Value GR20 Loud GR21 Medium GR22 Slight Beeper Timing Selection Barcode Barcode Label Description Value LB00 LED/Beep after transmission Use this barcode to indicate a "good read" after a barcode has been successfully decoded.
Page 19
ROGRAMMING UIDE Start Of Configuration Inter Message Delay Barcode Barcode Label Description Value IM01 0 ms IM02 100 ms IM03 500 ms IM04 1000 ms Inter Character Delay Barcode Barcode Label Description Value IC01 IC00 IC02 10ms IC03 20ms IC04 50ms IC05 End Of Configuration...
Page 20
ROGRAMMING UIDE Start Of Configuration Same Code Delay Barcode Barcode Label Description Value SD01 Same code delay time 50msec SD02 Same code delay time 100msec SD03 Same code delay time 200msec SD04 Same code delay time 300msec SD05 Same code delay time 400msec SD06 Same code delay time 500msec SD07...
Page 21
ROGRAMMING UIDE Start Of Configuration Blink Mode Selection (Only available in Auto Scan mode; barcode value SM02) Barcode Barcode Label Description Value LS00 Blink mode off. Module never enters blink mode LS01 Blink mode timer 5s LS02 Blink mode timer 10s LS03 Blink mode timer 15s LS04...
Page 22
ROGRAMMING UIDE Start Of Configuration Connection to an Omnidirectional Scanner Instead of connecting to a host, sometimes the handheld scanner is to be connected to the AUX port of an omnidirectional scanner and transmit data to the host system via this omnidirectional scanner.
Page 23
ROGRAMMING UIDE Start Of Configuration Operation Function Only Available for Handheld High-Speed Scanner Pulse Light Flash On/Off Timeout Duration Barcode Barcode Label Description Value FT01 Fast FT00 Medium FT02 Slow Blue LED Barcode Barcode Label Description Value LE00 When scanner on stand, blue LED remains off when decoding When scanner on stand, blue LED lights on when LE01...
ROGRAMMING UIDE Start Of Configuration Interface Configuration RS-232C Interface Setting Same Code Delay Barcode Barcode Label Description Value BR09 115200 BR08 57600 BR00 38400 BR01 19200 BR02 9600 BR03 4800 BR04 2400 BR05 1200 End Of Configuration Advanced Handheld CCD/Laser Scanner...
Page 25
ROGRAMMING UIDE Start Of Configuration Parity Bit Barcode Barcode Label Description Value PB01 Even parity PB02 Odd parity PB03 Mark parity PB04 Space parity PB05 None parity Stop Bit Barcode Barcode Label Description Value SB01 1 stop bit SB02 2 stop bit Data Bit Barcode Barcode Label...
Page 26
ROGRAMMING UIDE Start Of Configuration Handshaking Protocol Barcode Barcode Label Description Value HP01 None handshaking HP02 ACK/NAK HP03 Xon/Xoff HP04 RTS/CTS LB07 Enable BEEPER ON<BEL> CHARACTER LB08 Ignore BEEP ON <BEL> CHARACTER LB09 Disable ACK/NAK timeout beeper LB10 Enable ACK/NAK timeout beeper (three beeps) (Only available for Handheld High-Speed Laser Scanner) RT01 ACK/NAK response time 300ms...
Page 28
ROGRAMMING UIDE Start Of Configuration Keyboard Wedge and USB Interface Setting Language Support Barcode Barcode Label Description Value KL00 International Keyboard mode (ALT mode) KL01 Keyboard language support-USA KL02 Keyboard language support-UK KL03 Keyboard language support-Germany KL04 Keyboard language support-French KL05 Keyboard language support-Spanish KL06...
Page 29
ROGRAMMING UIDE Start Of Configuration Keyboard Setting Barcode Barcode Label Description Value CP00 Capital lock on CP01 Capital lock off CP05 Function key emulation enable CP06 Function key emulation disable CP18 Send number as normal data CP19 Send number as keypad data CP20 Alphabet follow as keyboard CP21...
Page 30
ROGRAMMING UIDE Start Of Configuration Want Emulation Setting Wand emulation is a standard interface but requires special firmware. If needed, please contact your distributor. Barcode Barcode Label Description Value WD01 All barcode will be decoded and transmitted in that symbology WD02 Enable Wand output data format as Code 39 WO01...
Page 31
ROGRAMMING UIDE Start Of Configuration Wand Emulation Speed Barcode Barcode Label Description Value WS03 Wand emulation speed---normal WS04 Wand emulation speed---high This option allows the transmission of wand emulation at 300us narrow element width WS05 Wand emulation speed---higher This option allows the transmission of wand emulation at 100 us narrow element width WS00...
ROGRAMMING UIDE Start Of Configuration The Symbologies Codabar Parameter Setting Barcode Barcode Label Description Value RC02 Codabar enable RD02 Codabar disable CB05 Codabar start/stop character transmission-none CB06 Codabar start/stop character transmission-A,B,C,D CB07 Codabar start/stop character transmission- DC1~DC4 CB08 Codabar start/stop character transmission- a/t,b/n,c/*,d/e CB09 Codabar maximum length setting...
Page 33
ROGRAMMING UIDE Start Of Configuration Barcode Barcode Label Description Value CB13 No check character CB14 Validate modulo 16,but don’t transmit CB15 Validate modulo 16 and transmit DC50 Codabar data redundant check=off DC51 Codabar data redundant check=1 DC52 Codabar data redundant check=2 DC53 Codabar data redundant check=3 End Of Configuration...
Page 35
ROGRAMMING UIDE Start Of Configuration Barcode Barcode Label Description Value 3905 Code 39 check digit calculate and transmit 3906 Code 39 check digit calculate but without transmit 3907 No check character 3908 Code 39 maximum length setting 3909 Code 39 minimum length setting Confirm to save this setting (required for reading full ASCII table and length setting) 3910...
Page 36
ROGRAMMING UIDE Start Of Configuration Code 93 Parameter Setting Barcode Barcode Label Description Value RC08 Code 93 enable RD08 Code 93 disable DC30 Code 93 data redundant check=off DC31 Code 93 data redundant check=1 DC32 Code 93 data redundant check=2 DC33 Code 93 data redundant check=3 9301...
Page 37
ROGRAMMING UIDE Start Of Configuration Code 128 Parameter Setting Barcode Barcode Label Description Value RC06 Code 128 enable RD06 Code 128 disable RC10 EAN-128 enable RD10 EAN-128 disable DC40 Code 128 data redundant check=off DC41 Code 128 data redundant check=1 DC42 Code 128 data redundant check=2 DC43...
ROGRAMMING UIDE Start Of Configuration Chinese Post Code Parameter Setting Barcode Barcode Label Description Value RC05 Chinese post code enable RD05 Chinese post code disable DC60 Chinese post code data redundant check=off DC61 Chinese post code data redundant check=1 DC62 Chinese post code data redundant check=2 DC63 Chinese post code data redundant check=3...
ROGRAMMING UIDE Start Of Configuration Code 11 Interface Setting Barcode Barcode Label Description Value RC07 Code 11 enable RD07 Code 11 disable 1101 Code 11 maximum length setting 1102 Code 11 minimum length setting Confirm to save this setting (required for reading full ASCII table and length setting) 1103 Code 11 one check digit verification...
Page 41
ROGRAMMING UIDE Start Of Configuration ITF 2 of 5 Parameter Setting Barcode Barcode Label Description Value RC04 ITF 2 of 5 enable RD04 ITF 2 of 5 disable RC09 IATA code enable RD09 IATA disable DC80 ITF 25 data redundant check=off DC81 ITF25 data redundant check=1 DC82...
Page 42
ROGRAMMING UIDE Start Of Configuration Barcode Barcode Label Description Value IT01 ITF 2 of 5 code maximum length setting IT02 ITF 2 of 5 code minimum length setting IT06 ITF 2 of 5 one fixed length setting IT07 ITF 2 of 5 two fixed length setting Confirm to save this setting (required for reading full ASCII table and length setting) IT08...
Page 43
ROGRAMMING UIDE Start Of Configuration Standard 2 of 5 Parameter Setting Barcode Barcode Label Description Value RC22 Standard 2 of 5 code enable RD22 Standard 2 of 5 code disable D051 Standard 2 of 5 code maximum length setting D052 Standard 2 of 5 code minimum length setting Confirm to save this setting (required for reading full ASCII table and length setting)
Page 44
ROGRAMMING UIDE Start Of Configuration Industrial 2 of 5 Parameter Setting Barcode Barcode Label Description Value RC21 Industrial 2 of 5 code enable RD21 Industrial 2 of 5 code disable D251 Industrial 2 of 5 code maximum length setting D252 Industrial 2 of 5 code minimum length setting Confirm to save this setting (required for reading full ASCII table and length setting)
ROGRAMMING UIDE Start Of Configuration Barcode Barcode Label Description Value UE10 Add on 5 only UE11 Add on 2 only UE12 Add on 2 or 5 UE13 Force UPC-E to UPC-A format enable UE14 Force UPC-E to UPC-A format disable UE15 Force UPC-A to EAN-13 format enable UE16...
ROGRAMMING UIDE Start Of Configuration Barcode Barcode Label Description Value DC12 UPC-A data redundant check=2 DC13 UPC-A data redundant check=3 DC14 UPC-E data redundant check=off DC15 UPC-E data redundant check=1 DC16 UPC-E data redundant check=2 DC17 UPC-E data redundant check=3 DC20 EAN-13 data redundant check=off DC21...
Page 49
ROGRAMMING UIDE Start Of Configuration UE35 EAN/UPC +add-on mandatory for 978/977 bookland (Supplement requirement, not sent for other) UE38 EAN/UPC +addon mandatory for 978/977 bookland (Supplement requirement, optionally for other) UE42 EAN/UPC +addon mandatory for 491 Japanese bookland (Supplement requirement, not sent for other) UE43 EAN/UPC +addon mandatory 491 Japanese bookland (Supplement requirement, optionally for other)
Page 50
ROGRAMMING UIDE Start Of Configuration Telepen Parameter Setting Barcode Barcode Label Description Value RC25 Telepen enable RD25 Telepen disable TE03 Telepen numeric mode enable TE04 AIM Telepen enable End Of Configuration Advanced Handheld CCD/Laser Scanner...
Page 51
ROGRAMMING UIDE Start Of Configuration Matrix 2 of 5 Parameter Setting Barcode Barcode Label Description Value RC12 Matrix 2 of 5 enable RD12 Matrix 2 of 5 disable D151 Matrix 2 of 5 maximum length setting D152 Matrix 2 of 5 minimum length setting Confirm to save this setting (required for reading full ASCII table and length setting) D153...
Page 52
ROGRAMMING UIDE Start Of Configuration GS1 DataBar Parameter Setting There are 7 kinds of barcodes in the GS1 DataBar family and they are categorized into three groups. Barcode types in the same group use the same barcodes for setting. Group Representative Contents Group 1...
Page 55
ROGRAMMING UIDE Start Of Configuration PDF417 Parameter Setting (Only available for Handheld High-Speed Laser Scanner) Barcode Barcode Label Description Value RC31 PDF 417 enable RD31 PDF 417 disable End Of Configuration Advanced Handheld CCD/Laser Scanner...
Page 58
ROGRAMMING UIDE Start Of Configuration Header and Trailer Barcode Barcode Label Description Value CP11 Add code length as header enable (2 digits) Add code length as header disable (2 digits) CP12 Header (Preamble) HT01 Trailer (Postamble) HT02 Truncate header character HT03 Truncate trailer character HT04...
Page 59
ROGRAMMING UIDE Start Of Configuration Multi-Barcode Editing Refer to Appendix 3 for detail setup steps. Function Setting Barcode Barcode Label Description Value MC00 Start to edit multi-barcode MC01 Multi-barcode enable MC02 Multi-barcode disable MC03 Apply output sequence In this mode, the scanner would retain the barcode data until it reads all the conditioned barcodes and transmit the data all together.
ROGRAMMING UIDE Start Of Configuration Barcode Type Setting Barcode Barcode Label Description Value Code39 Codabar ITF2 of 5 Code128 Code 93 Chinese Post Code EAN-8 EAN-13 UPC-A UPC-E GS1 DataBar Standard GS1 DataBar Expanded GS1 DataBar Limited End Of Configuration Advanced Handheld CCD/Laser Scanner...
ROGRAMMING UIDE Appendix 1: USB Virtual COM Driver Installation Contact your distributor to get the driver and follow the steps below to enable USB virtual COM port. Connect the handheld scanner and the host (e.g. a PC) with a USB interface cable. Enable USB virtual COM port with programming barcodes on page 8.
ROGRAMMING UIDE Appendix 2: Barcode Length Setting Introduction The length of a barcode is the number of characters it contains, including check digits. As listed in the Default Parameters section, each barcode type has different default length. You may change the setting by the following procedure. To set up barcode length, the paramours to be determined are barcode type and the desired barcode length.
ROGRAMMING UIDE Appendix 3: Multi-Barcode Editor Introduction The multi-barcode editor function allows users to set up the sequence of barcode data transmission. After the configuration, the scanner would transmit data in the pre- programmed sequence even if the user doesn’t scan barcodes in the correct order. Users can set up the sequence of up to 5 pieces of barcode data.
Page 64
ROGRAMMING UIDE Example If the barcode data transmission sequence and requirements are as below: The 1 barcode symbology The 2 barcode symbology Barcode type Code 128 Barcode type Code 39 Barcode length Barcode length No check on the first digit is First digit First digit required...
ROGRAMMING UIDE Start Of Configuration Appendix 4: Full ASCII Code 39 Table Hexa- Hexa- Code 39 ASCII Code 39 ASCII code code Full ASCII ---NUL Full ASCII ---SI Function key-----“Shift” Full ASCII ---SOH Full ASCII ---DLE Function key-----“Ins” Function key-----“5(num)” Full ASCII ---STX Full ASCII ---DC1 Function key-----“Del”...
Page 66
ROGRAMMING UIDE Start Of Configuration Full ASCII Code 39 Table Hexa- Hexa- Code 39 ASCII Code 39 ASCII code code Full ASCII ---RS Full ASCII ---- Function key-----“CTL(L)” Full ASCII ---US Full ASCII ---. Function key-----“ALT(L)” Full ASCII ---SP Full ASCII ---/ Full ASCII ---! Full ASCII ---0 Full ASCII ---“...
Page 67
ROGRAMMING UIDE Start Of Configuration Full ASCII Code 39 Table Hexa- Hexa- Code 39 ASCII Code 39 ASCII code code Full ASCII ---< Full ASCII ---K Full ASCII ---= Full ASCII ---L Full ASCII ---> Full ASCII ---M Full ASCII ---? Full ASCII ---N Full ASCII ---@ Full ASCII ---O...
Page 68
ROGRAMMING UIDE Start Of Configuration Full ASCII Code 39 Table Hexa- Hexa- Code 39 ASCII Code 39 ASCII code code Full ASCII ---Z Full ASCII ---i Full ASCII ---[ Full ASCII ---j Full ASCII ---\ Full ASCII ---k Full ASCII ---] Full ASCII ---l Full ASCII ---^ Full ASCII ---m...
Page 69
ROGRAMMING UIDE Start Of Configuration Full ASCII Code 39 Table Hexa- Code 39 ASCII code Full ASCII ---x Full ASCII ---y Full ASCII ---z Full ASCII ---{ Full ASCII ---| Full ASCII ---} Full ASCII ---~ Full ASCII ---DEL End Of Configuration Advanced Handheld CCD/Laser Scanner...