Description
Value Range
Default Value
ANNEX_G_STUN_MIN_KEEP_ALIVE
Value Format
Description
Value Range
Default Value
UDP_CON_REQ_ADDR_NOTIFY_LIMIT
Value Format
Description
Value Range
Default Value
5.3.10 XML Settings
XMLAPP_ENABLE
Value Format
Description
Value Range
Document Version 2015-02
Specifies the maximum period, in seconds, that STUN Binding
Requests must be sent by the CPE for the purpose of maintaining the
binding in the Gateway. This applies specifically to Binding Requests
sent from the UDP Connection Request address and port.
Note
•
This setting is available only when
"ANNEX_G_STUN_ENABLE" is set to "Y".
1–3600
300
INTEGER
Specifies the minimum period, in seconds, that STUN Binding
Requests can be sent by the CPE for the purpose of maintaining the
binding in the Gateway. This limit applies only to Binding Requests sent
from the UDP Connection Request address and port, and only those
that do not contain the BINDING-CHANGE attribute.
Note
•
This setting is available only when
"ANNEX_G_STUN_ENABLE" is set to "Y".
1–3600
30
INTEGER
Specifies the minimum time, in seconds, between Active Notifications
resulting from changes to the "UDPConnectionRequestAddress" (if
Active Notification is enabled).
0–65535
0
BOOLEAN
Specifies whether to enable the XML application feature.
•
Y: Enable XML application
•
N: Disable
5.3.10 XML Settings
Administrator Guide
183