Vqreport_Collector_Port; Vqreport_Send; Alert_Report_Trigger; Alert_Report_Mosq_Critical - Panasonic KX-HDV100 Administrator's Manual

Sip
Table of Contents

Advertisement

5.3.25 VQ Report by PUBLISH

VQREPORT_COLLECTOR_PORT

Value Format
Description
Value Range
Default Value
Web User Interface Reference

VQREPORT_SEND

Value Format
Description
Value Range
Default Value
Web User Interface Reference

ALERT_REPORT_TRIGGER

Value Format
Description
Value Range
Default Value
Web User Interface Reference

ALERT_REPORT_MOSQ_CRITICAL

Value Format
Description
Value Range
Default Value
Web User Interface Reference
236
Administrator Guide
INTEGER
Specifies the port of the collector server.
1–65535
5060
Port (Page 112)
INTEGER
Specifies the sending type of the VQ report using PUBLISH.
0: Disable
1: End of Session Report Using PUBLISH
2: Interval report Using PUBLISH
3: Alert Report Using PUBLISH
0
Enable PUBLISH (Page 112)
INTEGER
Specifies the trigger to notify the VQ report.
0: Warning
1: Critical
0
Alert Report Trigger (Page 113)
INTEGER
Specifies the critical criteria to send VQ report at the time of occurring
the MOSQ.
0–40
0
Threshold MOS-LQ (Critical) (Page 113)
Document Version 2015-02

Hide quick links:

Advertisement

Table of Contents

Troubleshooting

loading

Table of Contents