Removing and Replacing a Fan Module

Removing the Fan Module

58
RackSwitch G8052 Installation Guide
The rear panel of the G8052 has four bays for hot-swap fan modules. Four active
fan modules are required for redundancy.
With four fan modules, if one fan fails, the switch will send an error message and
continue operation. You can then replace the failed fan without powering off the
switch or disrupting switch functions. If a second fan fails, the switch will send
another error message, write a log message to flash memory, and shut down to
prevent overheating.
For proper airflow when operating the switch with three fan modules, the empty fan
bay must be closed with a blank fan filler plate.
To remove a hot-swap fan module, complete the following steps:
1. Loosen the retainer screw.
2. Grasp the extractor handle and gently pull the fan module from the slot.
Retainer Screw
Attention: If the inlet air temperature is above 35°C (95°F) while the switch is in
operation, replace the fan module within five minutes to avoid overheating the
switch.