Removing and Replacing a Power Supply Module

Removing the Power Supply Module

54
RackSwitch G8052 Installation Guide
To remove one of the SFP or SFP+ transceiver modules from the switch, complete
the following steps.
1. Disconnect the port cable from the transceiver.
2. Pull down the locking lever to release the transceiver.
3. Gently slide the transceiver out of the switch.
4. After you remove the transceiver, replace the safety cap.
To replace the transceiver module, see the appropriate section under
Transceivers" on page
The rear panel of the G8052 has two bays for hot-swap power supply modules. Two
active power supply modules are required for load-sharing and redundancy. If one
power supply module fails, you can replace it without powering off the switch or
disrupting switch functions.
For proper airflow when operating the switch with only one power supply module,
the empty power supply bay must be closed by a blank power filler plate.
Statement 5
CAUTION:
The power control button on the device and the power switch on the power
supply do not turn off the electrical current supplied to the device. The device
also might have more than one power cord. To remove all electrical current
from the device, ensure that all power cords are disconnected from the power
source.