2 – Front and rear panels–Rear Panel connectors
The pinout for this connector is given below .
Pin No.
Signal
1
PLAY
2
F FWD
3
REW
4
AUX 1
5
STOP
6
REC
7
AUX 2
8
CHASE
9
–
10
SUB GND
11
PLAY TALLLY
12
F FWD TALLY
13
REW TALLY
14
STOP TALLY
15
REC TALLY
16
LOCK TALLY
17
AUX 1 TALLY
18
AUX 2 TALLY
19
ACTIVE SENSE
s REMOTE IN/SYNC IN
This connector is used to connect another "master"
DTRS unit (e.g. DA-98HR, DA-78HR, DA-98, DA-
18
TASCAM DA-98HR
Pin No.
Signal
20
SUB GND
21
SERIAL OUT
22
–
23
SERIAL IN
24
–
25
–
26
–
27
–
28
–
29
–
30
–
31
–
32
SRCK
33
–
34
LOAD
35
–
36
SUB GND
37
SUB 5 V (max
50mA)
88 or DA-38). See 8, "DTRS synchronization" for
further details.
An RC-898, RC-848 or RC-828 remote control unit
may also be connected here, but unless an "HR
updated" RC-898 unit is used, not all functions of the
DA-98HR will be available from the remote control
unit.
t SYNC OUT
This is used to connect another DTRS unit in the
"daisy-chain" or, if this DA-98HR is the last unit in
the chain, to attach a termination plug.
u TDIF-1 (DIGITAL I/O)
This connector carries eight channels of digital audio
to and from the DA-98HR in TEAC Digital Interface
Format (TDIF-1).
v METER UNIT
This connector carries power and signals to drive 8
channels of the optional MU-8824 24-channel Meter
Unit.
Make the connection using a TASCAM PW-88M
cable.
w ~ IN
Use the provided AC power cord to connect the DA-
98HR to the AC power supply through this connec-
tor. Ensure that the power supplied is suitable for the
unit (as marked ). If you are in any doubt at all
regarding your power supply, consult a qualified
electrician.