jablotron JA-80K Oasis Installation Instructions Manual page 9

Table of Contents

Advertisement

other intruder detector within 40 minutes, an alarm will be
triggered. If the first triggered detector has a DEL reaction and
it is not confirmed by any other detector, it will not trigger an
alarm after the entrance delay has expired.
Exit delay beeps
Exit delay beeps while partially arming
Entrance delay beeps
Setting (arming) confirmation by wired-siren chirp
Siren always sounds during audible alarms
Wireless-siren alarms enabled (IW & EW)
Auto-bypass user approval via the ∗ key
If a detector is active during setting (arming), the system will
automatically bypass it (them), immediately (390), or after
keying in ∗ (391)
Final-door detectors
If this function is used, then Exit & Entrance delay settings are
multiplied by 30s. A triggered final-door detector extends the
exit delay, de-triggering of the last final-door detector ends the
exit delay.
Partial setting (arming) or system splitting
Automatic Summer Time (Daylight Saving Time)
Tamper-signal differential indication -
Tamper alarm in response to an increase in the
number of triggered tamper sensors
Operating the PG outputs using ∗8 and ∗9
Permanent alarm status display for a set system
Tamper alarm if unset (disarmed)
Recording PG output activation to memory
Engineer reset
Annual check requirement display
If enabled then 12 months after exiting Service Mode an
annual technical check request is displayed on the keypad unit
(mobile phone & ARC notification optional)
Only single alarm indication
If enabled then another intruder alarm can not be triggered
during an intruder alarm currently in progress.
Setting (arming) by service code
Audible panic alarm
Higher control-panel receiver-sensitivity
Extends the communication range if there is no RF
interference
Access by Code plus Card
If enabled and there is a code and card assigned to the same
user, then both of them must be presented for setting (arming)
control (in any order).
Audible 24h intruder alarm
Service mode only with Service + Master code
Installation manual: Oasis security system JA-80K
331 = YES
33x
341 = YES
34x
35x
351 = YES
36x
361 = YES
37x
371 = YES
38x
381 = YES
391 = YES
39x
0=none, 1=detectors 01 to 05,
65x
2=detectors 46 to 50
0 = unsplit system
66x
1 = partial setting (A, AB, ABC)
2 = split system A, B & common
section C (set if A & B are set)
680x
6801 = YES
ignore permanently
681x
6811 =
triggered tamper sensors, i.e.
only react to an increase in
the number of triggered
tamper sensors
react with a tamper
6810 =
alarm to all triggered tamper
sensors
6821 = YES
682x
683x
6831 = YES
684x
6841 = YES
6851 = YES
685x
6851 = YES
668x
690x
6901 = YES
691x
6911 = YES
692x
6921 = YES
693x
6931 = YES
6940 = normal
694x
6951 = Code+Card
695x
6950 = Code or Card
6961 = YES
696x
697x
6971 = YES
- 9 -
YES
330 = NO
NO
340 = NO
YES
350 = NO
NO
360 = NO
YES
370 = NO
YES
380 = NO
NO
390 = NO
x = 0
unsplit
NO
6800 = NO
X = 0
YES
6820 = NO
NO
6830 = NO
NO
6840 = NO
YES
6850 = NO
NO
6850 = N0
NO
6900 = NO
NO
6910 = NO
NO
6920 = NO
NO
6930 = NO
normal
6941 = higher
code or
card
YES
6960 = NO
NO
6970 = NO
is set (armed).
The last 5 s faster
The last 5 s faster
IW terminal only
NO = siren only
sounds if the system
is completely set
(armed)
to confirm auto-
bypass while exiting
Service mode press #
twice
If multiple F. door
detectors are used,
then triggered
state=any of them,
non triggered state=all
of them
Changes internal
clock + 1h on Apr.1 &
-1h on Nov.1
Suppresses the
indication of
permanently triggered
tamper sensors
if yes then arrow keys
can also operate PGX
suppresses the 3min.
display timeout
only with the master
code holder's
approval
MKE51801

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents