you for your patronage. We are confident that our excellent products and service can satisfy you. For your own safety, please read this user manual carefully before installing the device. In order to install , operate, and maintain the lighting safety and correctly. We suggest that the installation and operation should be done by the verified technician and follow the instruction strictly.
Page 3
• 4digit LED display • DMX-controlled operation or stand alone operation with Master/Slave-function ·Preset program: 8 built in programs can be called up via DMX controller • Software-upload by optional accessory via DMX line Overview (1) LEDS output (8) Power (2) Fixation screw Menu-button Floor stand...
SAFETY INSTRUCTIONS This device has left the factory in perfect condition. In order to maintain this condition and to ensure a safe operation, it is absolutely necessary for the user to follow the safety instructions and warning notes written in this user manual. If the device has been exposed to temperature changes due to environmental changes, do not switch it on immediately.
If the external flexible cable or cord of this luminaire is damaged, it shall be exclusively replaced by the manufacturer or his service agent or a similar qualified person in order to avoid a hazard. Please be aware that damages caused by manual modifications to the device are not subject to warranty.
If this device will be operated in any way different to the one described in this manual, the product may suffer damages and the guarantee becomes void. Furthermore, any other operation may lead to short-circuit, burns, electric shock, lamp explosion, crash, etc. INSTALLATION INSTRUCTIONS Mounting the device The applicable temperature for the lighting is between-25°C~45°C Do not use the...
Page 7
Installation method via clamp Screw one clamp each via a M12 screw and nut onto the Omega holders. Pull the safety-rope through the holes on the bracket of the base and over the trussing system or a safe fixation spot. Insert the end in the carabine and tighten the safety screw.
Page 8
Please note: to ensure maximal stability, when the voltage is 120V, only eight devices may be connected together in this manner! From the ninth device, please connect to power supply to get power for the second link; when the voltage is over 220V, only fifteen devices may be connected together in this manner! From the sixteenth device, please connect to power supply to get power for the second link.
OPERATION Display menu: A001~AXXX VALU (AXXX) DMX address setting <ADDR> SLAV ON/OFF Set as Slave RDMX ON/OFF Change address via DMX <RUN> AUTO ALON/MAST Run Auto program VALU D-XX D-00(DXXX) Display DMX value MODE FLIP ON/OFF Flip display D ON ON/OFF Delay shutting off LED display <DISP>...
<RED> RXXX(0-255) <GREN> GXXX(0-255) <BLUE> BXXX(0-255) MANL Manual adjust intensity <PROG> PXXX(0-255) <STRB> SXXX(0-255) <DIMM> DXXX(0-255) <LIFE> 0000~9999(HOURS) Life time of machine running TIME <CODE> CXXX Password of clear time ”038” <CLFE> ON/OFF Clear machine running time <STEP> S-01~S-48 Select steps of program REC.
Page 11
- Main menu 1. Press [MENU] to enter the main menu "MODE" (display flashing) Press [ENTER] and select "ADDR", “RUN” or "DISP" by pressing [UP] or [DOWN] button. 3. Press [ENTER] for selecting the desired sub menu. ——DMX address setting, Slave setting - DMX address setting With this function, you can adjust the desired DMX-address via the Control Board.
Page 12
3. Press [UP] to select “ON” if you wish to enable this function or press [DOWN] to select “OFF” if you don’t. 4. Press [ENTER] to confirm or press [MENU] to return to main menu. -DMX address setting via controller With this function, you can adjust the desired DMX-address via an external controller.
Page 13
1. Select “ALON” or “MAST” by pressing [UP] or [DOWN] button. 2. Press [ENTER] to confirm or Press [MENU] to return to the main menu. ——Display the DMX-value, Reverse display, Shut off LED display - Display the DMX 512 value of each channel With this function you can display the DMX 512 value of each channel.
Page 14
5. The display shows "D- XX”, ”X” stands for the DMX-value of the selected channel. - Reverse display With this function you can rotate the display by 180°. Select "FLIP" by pressing [UP] or [DOWN] button. Press [ENTER], the display shows “ON” or “OFF”. Press [UP] to select “ON”...
Page 15
——Main menu 1. Press [MENU] to enter the main menu (display flashing). 2. Press [UP] or [DOWN] button. to select “SET”. ——“CHAN” DMX channel MODE With this function you can choose DMX channel Mode 1. Select “CHAN” by pressing [UP] or [DOWN] button. 2.
Page 16
2. Press [ENTER], the display shows “ON” or “OFF”. 3. Press [UP] to select “ON” if you wish to enable this function or press [DOWN] button to “OFF” if you don’t. 4. Press [ENTER] to confirm or Press [MENU] to return to the main menu. ——Power on to preserve the MANL settings With this function you can activate.
Page 17
4. Press [ENTER] to confirm or Press [MENU] to return to the main menu. ——Main menu Press [MENU] to enter the main menu (display flashing). 2. Press [UP] or [DOWN] button to select “TIME”. 3. Press [MENU] to enter the main menu (display flashing). 4.
Page 18
With this function you can clear the running time of the device. 1. Select “CLFE” by pressing [UP] or [DOWN] button. 2. Press [ENTER], the display shows “ON” or “OFF”. 3. Press [UP] to select “ON” if you wish to enable this function or press [DOWN] button to “OFF”...
Page 19
Press [ENTER] to confirm or Press [MENU] to return to the main menu. -Auto Save With this function you can automatic save the number of steps in the Program Run. Select “REC” by pressing [UP] or [DOWN] button. Press [ENTER], the display shows “RE.XX”, “XX” stands for the number from 1 to 400.
11. Press [MENU] to exit. The number of steps can be defined under “STEP” and the scenes can be called up under “RUN”. b) Editing via the external controller Call up the first scene in your controller now. Press [ENTER], the display to be edited. Select “SC01”...
Page 21
0-255 Blue( 0-Black , 255-100% ) 0-10 No function 11-40 internal program 1 41-70 internal program 2 71-100 internal program 3 101-130 internal program 4 131-160 internal program 5 161-190 internal program 6 191-220 internal program 7 221-255 internal program 8 0-255 Red ( group1) 0-255...
The following to change the lens for the different angle CLEANING AND MAINTENANCE The following points have to be considered during the inspection: 1) All screws for installing the devices or parts of the device have to be tightly connected and must not be corroded.
Further instructions depending on the installation spot and usage have to be adhered by a skilled installer and any safety problems have to be removed. We recommend a frequent cleaning of the device. Please use a moist, lint- free cloth. Never use alcohol or solvents.