NEC Express 5800/140Rb-4 Service Manual page 127

Table of Contents

Advertisement

Error Code and Message
occurred.
|
0B35
0B50
CPU #1 with
error taken off
line.
0B51
CPU #2 with
error taken off
line.
0B52
CPU #3 with
error taken off
line.
0B53
CPU #4 with
error taken off
line.
0B5F
Forced to use
CPU with error
0B60
DIMM group #1
has been
disabled
0B61
DIMM group #2
has been
disabled
0B62
DIMM group #3
has been
disabled
0B70
An error
occurred during
temperature
sensor reading
0B71
System
Temperature out
of range
0B74
An error
occurredduring
voltage sensor
reading
0B75
System Voltage
out of range
0B78
An error
Description
Because an error
was detected in CPU
#1, it was degraded.
Because an error
was detected in CPU
#2, it was degraded.
Because an error
was detected in CPU
#3, it was degraded.
Because an error
was detected in CPU
#4, it was degraded.
CPU error is
detected.
A memory error was
detected in memory
DIMM group #1.
Memory DIMM group
#1 is degraded.
A memory error was
detected in memory
DIMM group #2.
Memory DIMM group
#2 is degraded.
A memory error was
detected in memory
DIMM group #3.
Memory DIMM group
#3 is degraded.
An error occurred
during sensor polling.
Abnormal
temperature was
detected.
An error occurred
during detection of
voltage.
Abnormal system
voltage was
detected.
An error was
Action
faulty fan indicated in the system event log.
The displayed CPU is degraded. Contact your
service representative to replace the failed CPU.
The system is started forcibly because errors are
detected on all CPUs. Contact your service
representative to replace the CPU.
Contact your service representative to replace the
DIMMs.
Contact your service representative.

Advertisement

Table of Contents
loading

Table of Contents