LOCATION 152: PROGRAMMING THE NUMBER OF DAYS LEFT UNTIL AUTOTEST REPORT
Location 152 contains the number of days left until the next autotest report. If this location contains a "0", an autotest
signal will be reported the first time the current time equals the autotest time programmed in locations 162-165.
Locations 098-099 must be programmed to enable autotest reporting.
LOCATION 153: PROGRAMMING THE CLOCK, CURRENT MONTH
Location 153 contains the current month. The month must be programmed using a number from "1" to "12". This
location must be programmed when using the maintenance code feature (see location 167).
LOCATION 154: PROGRAMMING THE CLOCK, CURRENT YEAR - TENS DIGIT
Location 154 contains the current year - tens digit. If the current year is 1994, this location should contain a 9, which is
the tens digit of the current year.
LOCATION 155: PROGRAMMING THE CLOCK, CURRENT YEAR - ONES DIGIT
Location 155 contains the current year - ones digit. If the current year is 1994, this location should contain a "4", which is
the ones digit of the current year. If the current year is 1995, this location should contain a "5", which is the ones digit of
the current year.
LOCATION 156: PROGRAMMING THE CLOCK, CURRENT DAY OF THE MONTH - TENS DIGIT
Location 156 contains the current day of the month - tens digit. If the current day of the month is the 5th (05), this
location should contain a "0", which is the current day of the month - tens digit. If the current day of the month is the
26th, this location should contain a "2".
LOCATION 157: PROGRAMMING THE CLOCK, CURRENT DAY OF THE MONTH - ONES DIGIT
Location 157 contains the current day of the month - ones digit. If the current day of the month is the 5th (05), this
location should contain a "5", which is the current day of the month - ones digit. If the current day of the month is the
26th, this location should contain a "6".
LOCATION 158: PROGRAMMING THE CLOCK, CURRENT HOUR - TENS DIGIT
Location 158 contains the current hour - tens digit. The time is entered in 24-hour time. If the current time is 5:25 PM,
the 24-hour time is 17:25, so this location should contain a "1", which is the current hour - tens digit. If the current time is
9:36 AM, the 24-hour time is 09:36, so this location should contain a "0".
LOCATION 159: PROGRAMMING THE CLOCK, CURRENT HOUR - ONES DIGIT
Location 159 contains the current hour - ones digit. The time is entered in 24-hour time. If the current time is 5:25 PM,
the 24-hour time is 17:25, so this location should contain a "7", which is the current hour - ones digit. If the current time
is 9:36 AM, the 24-hour time is 09:36, and this location should contain a "9".
LOCATION 160: PROGRAMMING THE CLOCK, CURRENT MINUTES - TENS DIGIT
Location 160 contains the current minutes - tens digit. The time is entered in 24-hour time. If the current time is 5:25 PM,
the 24-hour time is 17:25, so location 160 should contain a "2", which is the current minutes - tens digit. If the current
time is 9:36 AM, the 24-hour time is 09:36, and this location should contain a "3".
LOCATION 161: PROGRAMMING THE CLOCK, CURRENT MINUTES - ONES DIGIT
Location 161 contains the current minutes - ones digit. The time is entered in 24-hour time. If the current time is 5:25
PM, the 24-hour time is 17:25, so this location should contain a "5", which is the current minutes - ones digit. If the
current time is 9:36 AM, the 24-hour time is 09:36, and this location should contain a "6".
LOCATION 162: PROGRAMMING THE AUTOTEST TIME, HOUR - TENS DIGIT
Location 162 contains the tens digit of the hour that the autotest report is initiated. The time is entered in 24-hour time. If
the desired autotest time is 5:25 PM, the 24-hour time is 17:25, so this location should contain a "1", which is the tens
digit of the desired hour for autotest. If the desired autotest time is 9:36 AM, the 24-hour time is 09:36, and this location
should contain a "0".
LOCATION 163: PROGRAMMING THE AUTOTEST TIME, HOUR - ONES DIGIT
Location 163 contains the ones digit of the hour that the autotest report is desired. The time is entered in 24-hour time. If
the desired autotest time is 5:25 PM, the 24-hour time is 17:25, so this location should contain a "7", which is the ones
digit of the hour for autotest. If the desired autotest time is 9:36 AM, the 24-hour time is 09:36, and this location should
contain a "9".