LOCATION 120-121: PROGRAMMING TO REPORT AC POWER LOSS
The Ranger 8600E has the ability to report an AC power failure code when AC power is lost. This report can be
immediate or delayed depending on the information programmed in location 150 AC POWER LOSS DELAY. The
desired AC failure mode should be programmed in locations 120-121. If both locations are "0", AC power failures will not
be reported. Location 120 contains the standard digit, and location 121 contains the extended digit. When using 4+2
format, the number programmed in loc. 120 is sent as the "ones" digit. The "tens" digit is programmed in loc. 121.
LOCATION 122-123: PROGRAMMING TO REPORT LOW BATTERY
The Ranger 8600E can perform a dynamic battery test and report a low battery code when the battery has discharged
down to 10.3 volts. The desired low battery code is programmed in locations 122-123. If both locations are "0", low
battery will not be reported. Location 122 contains the standard digit, and location 123 contains the extended digit.
When using 4+2 format, the number programmed in location 122 is sent as the "ones" digit. The "tens" digit is
programmed in location 123.
LOCATION 124: PROGRAMMING FOR PRIORITY ZONE TROUBLE REPORTING
The Ranger 8600E has the ability to report a trouble code each time a Priority zone opens. The desired trouble code is
programmed in location 124. If this location contains a "0", the Priority Trouble will not be reported.
LOCATION 125: PROGRAMMING FOR ZONE BYPASS REPORTING
The Ranger 8600E has the ability to report a bypass on zones 1-6. The desired bypass code is programmed in location
125. If this location contains a "0", zone bypass will not be reported. When using 4+2 format, the number programmed in
this location is sent as the "tens" digit. The "ones" digit is the zone communicator code. The bypass will be reported at
the end of the exit delay for non-24 hour zones. 24-hour zones will report a bypass immediately. When a bypass is
removed, a restore will be reported if "Restore" is enabled in location 126.
LOCATION 126: PROGRAMMING THE COMMUNICATOR CODE FOR RESTORAL
Location 126 contains the communicator code that will be sent for restoral of a zone. If this location contains a "0", no
restorals will be reported. If a restoral code is programmed and an extended format is selected, the restorals will be
reported by zone. If a restoral code is programmed and an extended format is not selected, a restoral code will be sent
when all of the previously reported conditions have restored. When using 4+2 format, the number programmed in this
location is sent as the first, or "tens" digit. The second, or "ones" digit will be the "ones" digit of the zone or condition that
restored.
LOCATION 127: PROGRAMMING THE COMMUNICATOR CODE FOR CANCEL (EXCEPTION OPENING)
Location 127 contains the communicator code that will be sent for cancel. The cancel code programmed in this location
will be sent if an arm/disarm code is entered after a trip on zones 1 through 6 has been reported (excluding 24-hour
zones). After a cancel has been reported, no loop restorals will be transmitted on non-24 Hour zones. If this location
contains a "0", cancel is disabled. When using 4+2 format, the number programmed in this location is sent as the "tens"
digit. The "ones" digit is the man number of the person that canceled. When using a remote arming input, the man
number is 1.
LOCATION 128: PROGRAMMING THE COMMUNICATOR TO ABORT
The number programmed in location 128 will be the number of two-second increments the 8600 will delay before
attempting to communicate an alarm on a non-24 hour zone. NOTE: This feature shall not be enabled on UL Listed
systems.
LOCATION 129: PROGRAMMING FOR SILENT PANIC/HOLD-UP
Location 129 is used to silence the audible output for a panic/hold-up alarm. Programming a "1" in this location will
silence the audible output during a panic/hold-up alarm. If this location contains a "0", the Ranger 8600E will have an
audible panic/hold-up output. Program a "2" to silence Keypad Sounder during alarm.
LOCATION 130: ENABLING THE SWINGER SHUTDOWN
Location 130 is used to enable the burglary zone swinger shutdown. The number programmed in this location will
determine the number of trips the Ranger 8600E will allow, before bypassing all burglary zones (1-6) which have tripped
during an arming cycle. The bypassed zones will not report trips to a central station, and the local siren or bell will not
sound for these zones. A zone trip will not be added to the number count until after the zone has tripped more than
once. If this location contains a "0", this feature is disabled. A zone which has been bypassed by this feature will be
reported if bypass reporting is enabled in location 125. NOTE: This feature shall not be enabled on UL listed
systems.