CADDX 8600 Manuals
Manuals and User Guides for CADDX 8600. We have
3
CADDX 8600 manuals available for free PDF download: Installation Manual, Manual, User Manual
CADDX 8600 Installation Manual (39 pages)
Downloadable Control Communicator
Brand:
CADDX
| Category:
Cell Phone
| Size: 4 MB
Table of Contents
Table of Contents
2
General Description
3
Standard Parts List
3
Optional Parts List
3
Parts Diagram
4
Terminal Drawing and Special Notes
5
Terminal Description
6
Programming
7
Programming Example
8
#8950 Programmer
8
Locations 032-047: Programming the Primary Telephone Number
9
Locations 048-051: Programming the Account Code for the Primary Phone Number
9
Location 052: Programming Communicator Format for the Primary Phone Number
9
Location 053: Disabling the Secondary Telephone Number as a Backup
9
Locations 054-069: Programming the Secondary Telephone Number (Split Reporting)
10
Location 074: Programming Communicator Format for the Secondary Telephone Number
10
Arm/Disarm Codes
11
Phone Numbers Account Code and Format
11
Optional Control and Communicator Features
11
Communicator Codes
11
Communicator Format Selections
14
Locations 000-003: Programming the Master Arm/Disarm Code
15
Locations 004-0023: Programming the Arm/Disarm Code for Users 2-6
15
Locations 024-027: Programming the Duress Code for User 7
15
Locations 028-031: Programming the "Go to Program" Access Code
15
Location 075: Programming the Entry Delay Time
16
Location 076: Programming the Exit Delay Time
16
Location 077: Programming the Siren Shutdown/Recycle Timeout
16
Locations 078-083: Programming the Zone Types
16
Zone Characteristics Descriptions
17
Location 086-087: Programming the Ranger 8600 for Duress Code Capability
17
Location 088-089: Programming for Auxiliary 1
18
Location 090-091: Programming for Auxiliary 2
18
Location 092-093: Programming for Keypad Panic
18
Location 094-095: Programming the Tamper Feature
18
Location 096-097: Programming to Report Download Complete
19
Location 098-099: Programming for Autotest Reports
19
Location 102: Programming to Report Closings
19
Location 103: Programming to Report Openings
19
Location 104-105: Programming the Communicator Code for Zone 1
20
Locations 106-115: Programming the Communicator Code for Zones 2-6
20
Location 120-121: Programming to Report AC Power Loss
21
Location 122-123: Programming to Report Low Battery
21
Location 124: Programming for Priority Zone Type Trouble Reporting
21
Location 125: Programming for Zone Bypass Reporting
21
Location 127: Programming the Communicator Code for Cancel (Exception Opening)
22
Location 128: Programming the Communicator to Abort
22
Location 129: Programming for Silent Panic/Hold-Up
22
Location 130: Enabling the Swinger Shutdown
22
Location 132: Built-In Siren Driver/1 Amp Voltage Output
23
Location 133: L.E.D. Extinguish Feature
23
Location 134: Entering the Number of Dial Attempts
23
Location 135: Power up Condition
23
Location 139: Programming the Quick Arm Digit
24
Location 140: Priority Siren Cutoff Inhibit
24
Location 141: Double Line Extended Alarm Reporting
24
Location 142: Siren/Bell Test Feature
24
Location 145-148: Programming the Auxiliary Outputs
25
Location 149: Inverting the Auxiliary Outputs
25
Location 150: AC Power Loss Delay Feature
25
Location 151: Programming the Number of Rings to Answer Download Call
25
Location 152: Programming the Number of Days Left until Autotest Report
26
Location 153: Programming the Current Month
26
Location 155: Programming the Current Year - Tens Digit
26
Location 156: Programming the Current Day of the Month - Tens Digit
26
Location 160: Programming the Current Minutes - Tens Digit
27
Location 161: Programming the Current Minutes - Ones Digit
27
Location 162: Programming the Hour for Autotest - Tens Digit
27
Location 163: Programming the Hour for Autotest - Ones Digit
27
Location 166: Programming the Autotest Time Reporting Interval
28
Location 168-171: Programming the Seed Code for Rotating Maintenance Codes
28
Location 172: Programming User 7 or Maintenance Code Dor Opening Communicator Code
28
Location 173: Programming User 7 or Maintenance Code Closing Communicator Code
28
Location 174: Programming Zones 3 through 6 for Normally Closed Operation Only
29
Location 175: Programming Zones 1 And/Or 2 for Normally Closed Operation Only
30
Location 176: Split Reporting - Programming Tamper, Download Complete, and Autotest to Report to the Secondary Phone Number
30
Location 177: Split Reporting - Programming AC Power Fail, Low Battery, Open/Close, and Maintenance Open/Close to Report to the Secondary Phone Number
31
Location 178: Programming the Secondary Entry Delay (Zone Type 9)
31
Location 179: Programming the Secondary Exit Delay (Zone Type 9)
32
Location 180: Programming the Loop Response Time
32
Locations 181-185: Do Not Program These Locations
32
Locations Accessible Only through Downloading
32
General Operating Instructions
33
Arming and Disarming the Ranger 8600
33
Bypassing Zones
33
Entering and Changing the Master Code (User Code #1)
33
Entering and Changing an Auxiliary Code
34
Removing Auxiliary Codes
34
Quick Arm Feature
34
Arming and Disarming with Automatic Bypass/Instant Arming
34
Door Chime Annunciation
35
Smoke Detector Reset
35
Alarm History
35
Siren/Bell Test Feature
35
Keypad Operation
36
Keypad Sounder
36
Local Telephone Company Interface Information
37
Telephone Connection Requirements
37
Incidence of Harm
37
Changes in Telephone Company Equipment or Facilities
37
Specifications
38
Advertisement
CADDX 8600 User Manual (8 pages)
Brand:
CADDX
| Category:
Security System
| Size: 0 MB
Table of Contents
How to Bypass Zones
2
Quick-Arm Feature
2
How to Arm Your Security System
2
How to Disarm Your Security System
2
Automatic Bypass Option
3
Instant / Delay Option
3
Group Bypass Option
3
Force Arming Option
3
Automatic Arming Option
3
The Chime Feature
4
Keypad Activated Panic/Hold-Up Alarm
4
Keypad Activated Fire Alarm
4
Keypad Activated Auxiliary Alarm
4
Telephone Line Monitor
4
Duress Code
5
Fire Zone
5
Programming Arm/Disarm Codes
5
Audible Alarm Sounds
6
Keypad Control Tones (Beeps)
6
Resetting Your Security Control Center
6
Keypad Control Light Indicators
6
Service Condition
7
Testing Your Security System
7
CADDX 8600 Manual (11 pages)
REV F
Brand:
CADDX
| Category:
Security System
| Size: 0 MB
Table of Contents
Security System Notes
1
Security System Configuration
1
How to Bypass Zones
3
Quick-Arm Feature
3
Programming Access Codes
5
Changing the Master Code
5
Fire Zone
5
Duress Code
6
Audible Alarm Sounds
6
Keypad Control Tones (Beeps)
7
Testing Your Security System
7
Emergency Evacuation Plans
8
System Notes
9
Advertisement
Advertisement
Related Products
CADDX 8600UF98
CADDX Ranger 8980E
CADDX Ranger 8980
CADDX Ranger 8000
CADDX Ranger 8600E
CADDX Ranger 8800
CADDX NetworkX NX-6
CADDX networx nx-4
CADDX NetworX NX-8
CADDX NX-6
CADDX Categories
Security System
Keypad
Cell Phone
Receiver
Touch Panel
More CADDX Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL