Page 1
DHC 8 EL English Instantaneous water heater - Operation and installation instructions This water heater must be installed (water and electrical installation), commissioned and serviced by approved service technicians in accordance with these instructions.
Page 3
- Children should be supervised to ensure that they do not play with the appliance. STIEBEL ELTRON...
Page 4
1.1 Description of the unit. of ~ 50 C The DHC 8 EL fully electronic instanta - Level heats the water to a neous water heater heat the water while it maximum temperature is owing through the unit.
Operation Instruction for the user and the quali ed installer The DHC 8 EL water heater unit is 1.4 This model features an automatic to be installed in a closed, frost-free cuto device that functions when the room (disconnected units are to be stored in water temperature is unusally high.
Page 6
2. First Operation - The indicator light will show. - The DHC 8 EL Water Heater features The water heater should rst be operated a temperature control knob at the front by an expert technician only.
Operation Instruction for the user and the quali ed installer 3. Technical Data Type DHC 8 EL Norminal capacity 0.45 Design Close outlet Max. water pressure 1000 kPa Min. water pressure to activate unit 200 kPa Water connection G ½“ (External Thread) (15mm)
/ or your country. unauthorized installers. The installation, electrical connection and rst operation of this appliance should be carried out by a quali ed installer. STIEBEL ELTRON...
Page 9
- Increase ow volume through the unit. required for the unit to turn it on has not been reached. - Water ow too high - Reduce water ow - Heating setting too low - Turn knob to the right (max. position) STIEBEL ELTRON...
9. Reed switch (Fig 7#3) 10. Cold water connection 4. Distance of the connection 11. Hot water connection cable (Fig 6#4) 12. Flow limiter 5. Thermostat 6. Cable entry with seal Description of the unit (Internal) Fig 3 STIEBEL ELTRON...
Page 11
Installation Instruction for the quali ed installer Installation to a shower / sink. Fig 4 Dimension Cable 65 mm G1/2 100 mm 35 mm 110 mm. 200 mm Fig 5 Fig 6 STIEBEL ELTRON...
Page 12
D - Thermal cut-out 4 x 35 mm E - Temperature Sensor (Inlet) 6 mm F - Temperature Sensor (Outlet) Fig 7 Fig 8 G - ELCB (option) Wall Mounting 4 x 35 mm 4,3 mm Fig 9 STIEBEL ELTRON...
Page 13
- Create an opening for the water - Remove the screw from underneath inlet in the case of wall-embeded and the water heater to open the cover of the wall-mounted pipes. unit. (concealed connection) Fig 11 Fig 13 STIEBEL ELTRON...
Page 14
- Insert the wires into the respective openings according to the diagram, and fasten the screws to secure the wires tightly. Please en- sure that the correct size of wire is used. STIEBEL ELTRON...
Page 15
The cold water pipe must be turned to the joints (both hot and cold water), using a on in order to rinse it before rubber leakage gasket (Fig 18/C) between installation. Pressure-resistant equipment the joints. must be used in compliance with accepted standards. STIEBEL ELTRON...
Page 16
- Install the cover. Connect the power - After installation is complete, close cord between the circuit board and the cover. the casing and screw in tightly. Fig 22 Fig 20 Fig 21 ig 21 STIEBEL ELTRON...