STIEBEL ELTRON DHC 3 Operation And Installation
STIEBEL ELTRON DHC 3 Operation And Installation

STIEBEL ELTRON DHC 3 Operation And Installation

Hydraulically controlled small instantaneous water heater

Advertisement

BEDIENUNG UND INSTALLATION
OPERATION AND INSTALLATION
UTILISATION ET INSTALLATION
OPERACIÓN E INSTALACIÓN
OBSŁUGA I INSTALACJA
ЭКСПЛУАТАЦИЯ И УСТАНОВКА
‫االستعمال والتركيب‬
Hydraulisch gesteuerter Kleindurchlauferhitzer | Hydraulically controlled small
instantaneous water heater | Petit chauffe-eau instantané à commande hydraulique |
Minicalentador de control hidráulico | Hydraulicznie sterowany mały ogrzewacz
przepływowy | Компактный проточный нагреватель с гидравлическим управлением |
‫سخان المياه الفوري الصغير ذو التحكم الهيدروليكي‬
» DHC 3
» DHC 4
» DHC 6
» DHC 8
» DHC 6 U

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DHC 3 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for STIEBEL ELTRON DHC 3

  • Page 1 | Petit chauffe-eau instantané à commande hydraulique | Minicalentador de control hidráulico | Hydraulicznie sterowany mały ogrzewacz przepływowy | Компактный проточный нагреватель с гидравлическим управлением | ‫سخان المياه الفوري الصغير ذو التحكم الهيدروليكي‬ » DHC 3 » DHC 4 » DHC 6 » DHC 8...
  • Page 2: Table Of Contents

    “Specification / Data table”). Factory settings ������������������������������������������������� 20 Installation �������������������������������������������������� 20 - Drain the appliance as described in chap- 10.1 Alternative installation options only for DHC 3, DHC 4, ter “Installation / Maintenance / Draining the DHC 6, DHC 8 ���������������������������������������������������� 21 appliance”. 10.2 Completing the installation �����������������������������������...
  • Page 3: General Information

    OPERATION General information OPERATION Symbol Meaning Material losses (appliance damage, consequential losses and environmen- tal pollution) Appliance disposal General information The chapters “Special Information” and “Operation” are intended f This symbol indicates that you have to do something. The ac- for both the user and qualified contractors.
  • Page 4: Appliance Description

    OPERATION Appliance description Appliance description Troubleshooting Problem Cause Remedy The hydraulically controlled small instantaneous water heater is The appliance will not There is no mains volt- Check the fuse/MCB in switched on automatically by the hydraulic control unit. start despite the DHW age at the appliance.
  • Page 5: Installation

    Always install the appliance vertically near the draw-off - Connector point. - Flat gaskets Oversink installation DHC 3, DHC 4, DHC 6, DHC 8 - 2 fixing screws 4 x 35 and rawl plugs - Washer - Installation template in the centre part of these instructions...
  • Page 6: Factory Settings

    This chapter describes installations in accordance with the factory settings. For further installation options for the DHC 3, DHC 4, DHC 6 and DHC 8 appliances, see chapter "Alternative installation options". 1 Power supply from below 4 x 35 4,5 - 5,5 f Undo the cover fixing screw by two turns.
  • Page 7: Dhc 6, Dhc 8

    Mount the appliance back panel over the screws and slide the appliance back panel downwards. f DHC 3, DHC 4, DHC 6, DHC 8: Secure the connection pipes with the supplied flat gaskets onto the connectors. f Align the appliance and tighten the fixing screws securely.
  • Page 8: Completing The Installation

    INSTALLATION Installation Power supply from above on finished walls DHC 3, DHC 4, f Cut an opening in the cable grommet suitable for the select- DHC 6, DHC 8 ed power cable (for positions of the connections, see chapter "Specification").
  • Page 9: Commissioning

    INSTALLATION Commissioning 11.2 Recommissioning Alternative cap fixing only for DHC 6 U In the case of a limited clearance between the appliance and the Material damage floor, use the hexagon screws supplied to secure the cap. After an interruption in the water supply, recommission the appliance by carrying out the following steps in order DHC 6 U to prevent irreparable damage to the heating system.
  • Page 10: Specification

    You can clean the fitted sieve after removing the cold water con- nection pipe. 15. Specification 15.1 Dimensions and connections DHC 3, DHC 4, DHC 6, DHC 8 90° 1 Earth screw 2 Strainer 3 Cold water connection pipe f Undo the earth screw by approx.
  • Page 11: Wiring Diagram

    INSTALLATION Specification 15.2 Wiring diagram Alternative connection options DHC 3, DHC 4, DHC 6, DHC 8 DHC 3, DHC 4 1/N/PE ~ 220 ... 240 V b02 Entry electrical cables 1 DHC 6, DHC 8, DHC 6 U Cold water inlet...
  • Page 12: Application Areas

    15.4 Application areas See chapter "Data table". 15.5 Details on energy consumption Product data complies with EU regulations relating to the Directive on the ecodesign of energy related products (ErP). DHC 3 DHC 4 DHC 6 DHC 8 DHC 6 U...
  • Page 13: Data Table

    INSTALLATION | GUARANTEE | ENVIRONMENT AND RECYCLING Specification 15.6 Data table DHC 3 DHC 4 DHC 6 DHC 8 DHC 6 U 073478 073715 073480 073481 073479 Electrical details Rated voltage Rated output Rated current 12,2 13,0 13,4 18,1 19,1...
  • Page 14   Deutschland Verkauf Tel. 05531 702-110 | Fax 05531 702-95108 | info-center@stiebel-eltron.de STIEBEL ELTRON GmbH & Co. KG Kundendienst Tel. 05531 702-111 | Fax 05531 702-95890 | kundendienst@stiebel-eltron.de Dr.-Stiebel-Straße 33 | 37603 Holzminden Ersatzteilverkauf Tel. 05531 702-120 | Fax 05531 702-95335 | ersatzteile@stiebel-eltron.de Tel.

This manual is also suitable for:

Dhc 6 uDhc 4Dhc 8

Table of Contents