Powering on UC-7420/7410

Connect the SG wire to the Shielded Contact located in the upper left corner of the UC-7420/7410,
and then power on UC-7420/7410 by connecting it to the power adaptor. It takes about 30 to 60
seconds for the system to boot up. Once the system is ready, the Ready LED will light up, and the
Network address settings will appear on the LCM display.
NOTE
After connecting UC-7420/7410 to the power supply, it will take about 30 to 60 seconds for the
operating system to boot up. The green Ready LED will not turn on until the operating system is
ready.

Connecting UC-7420/7410 to a PC

There are two ways to connect UC-7420/7410 to a PC: through the serial Console port or via
Telnet over the network.

Serial Console

The serial console port gives users a convenient way of connecting to UC-7420/7410's console
utility. This method is particularly useful when using UC-7420/7410 for the first time. The signal
is transmitted over a direct serial connection, so you do not need to know either of
UC-7420/7410's two IP addresses in order to connect to the serial console utility.
Use the serial console port settings shown below.
Baud rate
Parity
Data bits
Stop bits:
Flow Control
Terminal
Once the connection is established, the following window will open.
To log in, type the Login name and password as requested. The default values are both root:
Login:
Password: root
115200 bps
None
8
1
None
VT100
root
2-2
Getting Started