Sleep Mode Operation - Panasonic CS-E9BKP Service Manual

Room air conditioner
Table of Contents

Advertisement

CS-E9BKP CU-E9BKP5 / CS-E12BKP CU-E12BKP5
The operation mode chart for this example is as shown in below figure and the operation mode to be performed will depend on
indoor intake air temperature and outdoor air temperature at the time when the judgment is made.
8.1.9.

Sleep Mode Operation

1. Sleep Mode operation starts by pressing the button at remote controller and the operation last for a maximum of 10 hours. The
Sleep Shift operation starts when the intake air temperature = internal setting temperature or one hour after Sleep Mode
operation starts
2. For Cooling Mode or Soft Dry Mode operations, during Sleep Shift operation, indoor fan motor will operate at Lo speed and SLo
speed respectively. The internal setting temperature is shifted as stated in below figure and table.
Condition
Remote Controller Setting
Temperature (°C)
26
27
28
Outdoor Air
Temperature (°C)
< 25
+2
25
+2
< 25
+2
25
+2
+2
26
Shifting Temperature (°C)
Cooling Mode
A
B
C
+3.0
+4.0
+5.0
+1.5
+3.0
+3.5
+4.0
+1.5
+3.0
+4.0
+4.0
+1.5
+3.0
+3.5
+4.0
+1.5
+3.0
+3.0
+3.0
+1.5
Soft Dry Mode
A
B
C
+2.0
+3.0
+4.0
+2.0
+2.5
+3.0
+2.0
+3.0
+3.0
+2.0
+2.5
+3.0
+2.0
+2.0
+2.0