Panasonic CS-E9BKP Service Manual page 17

Room air conditioner
Table of Contents

Advertisement

Table (a): Auto Operation Mode Setting
Cooling/Soft Dry → Heating
Heating → Cooling/Soft Dry
Table (b): Outdoor Air Temperature Shifting
Cooling/Soft Dry
Heating
Table (c): Powerful Mode Shifting
Cooling
Soft Dry
Heating
Table (d): Fan Speed Shifting
Cooling
Soft Dry
Heating
Table (e): Start-Up Shifting
Cooling/Soft Dry
Heating
Table (f): Soft Dry Mode Shifting
Soft Dry
Mode Shift:
Mode:
Outdoor Temperature, X (°C):
Mode:
Period, X (min):
Mode:
Me-, Me, Me+, Hi, Auto
Mode within 60 Minutes from Start-up:
Mode:
Temperature Shift (K)
E9BKP
-2.0
+2.0
Temperature Shift (K)
E9BKP
X
30
0.0
X < 30
+0.5
X
9
0.0
5
X < 9
+0.5
1
X < 5
+1.0
X < 1
+1.5
Temperature Shift (K)
E9BKP
X < 20
-2.0
X
20
0.0
X < 20
-1.0
X
20
0.0
X < 20
+3.5
X
20
+3.5
Fan Speed:
Temperature Shift (K)
E9BKP
All
+1.5
All
+1.0
Lo
+1.0
+0.5
Temperature Shift (K)
E9BKP
-1.0
+2.0
Temperature Shift (K)
E9BKP
+1.0
17
CS-E9BKP CU-E9BKP5 / CS-E12BKP CU-E12BKP5
E12BKP
-2.0
+2.0
E12BKP
0.0
+0.5
0.0
+1.0
+1.5
+2.0
E12BKP
-2.0
0.0
-1.0
0.0
+3.5
+3.5
E12BKP
+1.5
+1.0
+1.0
+0.5
E12BKP
-1.0
+2.0
E12BKP
+1.0

Hide quick links: